In primary and revision total hip arthroplasty (THA), the acetabular component continues to pose greater challenges than the femoral component. Numerous factors lead to polyethylene wear, which subsequently affects primary THA survival. Progressive polyethylene wear is associated with the occurrence of osteolysis, especially overlying the acetabulum, which can lead to component loosening and subsequent revision. Polyethylene failure usually manifests as massive liner wear up to the metal shell, fracture of the liner, or a combination of both. There is often a small amount of metallosis associated with this pathology. To our knowledge, massive wear of the acetabular metal shell, however, has not previously been reported in the literature. This article describes a case of massive wear through a polyethylene liner and the acetabular metal shell of an Acetabular Cup System (DePuy, Leeds, United Kingdom) that presented as an apparent dislocation 13 years following the index operation. The pseudodislocation was intraoperatively found to be penetration of the femoral head through the acetabular shell. The acetabular component was consequently revised to a larger cementless cup. The femoral component was mechanically stable and required no revision. Patients with long-standing Acetabular Cup System THA may experience acetabular metal shell wear-through phenomena presenting as a pseudodislocation, and this possibility should be taken into consideration during preoperative planning.
机译:在原发和翻修全髋关节置换术(THA)中,髋臼组件比股骨组件继续面临更大的挑战。许多因素导致聚乙烯磨损,继而影响初级THA存活率。聚乙烯的逐渐磨损与骨溶解的发生有关,尤其是覆盖在髋臼上,这可能导致组件松动和随后的翻修。聚乙烯失效通常表现为大量衬板磨损至金属外壳,衬板断裂或两者兼而有之。这种病理学常伴有少量的金属病。据我们所知,先前没有文献报道髋臼金属壳的大量磨损。本文介绍了通过聚乙烯衬里和髋臼杯系统(DePuy,利兹,英国)的髋臼金属外壳大量磨损的情况,该事件在分度手术后13年出现明显的脱位。术中发现假性脱位是股骨头穿过髋臼壳的穿透。髋臼组件因此被修改为更大的无骨水泥杯。股骨组件机械稳定,无需翻修。长期使用髋臼杯THA的患者可能会出现髋臼金属壳磨损现象,表现为假性脱位,因此在进行术前计划时应考虑这种可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号