The present in vitro study aimed to assess the effects of root surface mechanical instrumentation on the marginal integrity and adaptation of resin composite crowns. The following null hypotheses were tested: no differences exist between finish line and 1) marginal gap or 2) marginal microleakage before and after manual mechanical periodontal maintenance. A total of 56 intact human mandibular molars were randomly distributed into four groups and subjected to standardized tooth preparations for indirect composite crowns with different marginal finish lines (90° shoulder, beveled 90° shoulder, feather edge, chamfer). One-half of the specimens was used as a control and remained untreated, and the remaining half was subjected to root surface procedures simulating five years of semestral mechanical supportive periodontal treatment. The marginal gap and microleakage were evaluated and statistically analyzed. The specimens used as controls showed lower mean marginal gaps than those subjected to the simulated periodontal treatment, whereas the latter showed lower microleakage than the control crowns. Statistically significant differences were recorded for both the experimental variables. The root surface procedures resulted in altered surfaces of the composite crowns. The marginal gap increased after the treatment, whereas the marginal microleakage was reduced. The 90° shoulder and the chamfer preparation could be considered a viable option to fabricate composite crowns, but the beveled 90° shoulder and the feather edge should not be recommended.
机译:本体外研究旨在评估牙根表面机械器械对树脂复合材料牙冠的边缘完整性和适应性的影响。测试了以下零假设:终点线与手动机械牙周维护前后的边缘间隙或2)边缘微渗漏之间没有差异。总共将56个完整的人类下颌磨牙随机分为四组,并对其进行标准的牙齿准备,以制备具有不同边缘终点线(90°肩,90°斜角肩,羽缘,倒角)的间接复合冠。一半的样本用作对照,未进行任何处理,其余的一半进行了根表面处理,模拟了五年的半机械支持性牙周治疗。对边缘间隙和微渗漏进行了评估和统计分析。用作对照的样本显示出的平均边缘间隙比经过模拟牙周治疗的样本低,而后者显示的微渗漏率低于对照牙冠。记录了两个实验变量的统计学差异。根部表面处理导致复合材料牙冠的表面改变。治疗后边缘间隙增加,而边缘微渗漏减少。 90°的肩部和倒角准备可以被认为是制造复合材料冠冕的可行选择,但不建议使用90°斜角的肩部和羽毛边缘。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号