Influence of delayed placement of composites over cured adhesives on dentin bond strength of single-application self-etch systems.

机译:复合材料在固化粘合剂上的延迟放置对单次应用自蚀系统的牙本质粘合强度的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

This study examined the relationship between delay in composite placement over cured adhesives and the dentin bond strength of several single-application self-etch adhesive systems. The adhesive system/resin composite combinations used were: Adper Prompt L-Pop/Filtek Z250 (AP), AQ Bond Plus/Metafil C (AQ), Fluoro Bond Shake One/Beautifil (FB), G-Bond/Solare (GB), One-Up Bond F Plus/Palfique Estelite (OF), Xeno IICF Bond/Xeno CF (XE). Bovine mandibular incisors were mounted in self-curing resin and wet ground with #600 SiC to expose labial dentin. The adhesives were applied according to each manufacturer's instructions, and resin pastes were condensed into a mold (o4x2 mm) immediately, and 1, 2, 5 and 10 minutes after light irradiation of the adhesives. Ten samples per test group were stored in 37 degrees C water for 24 hours, then shear tested at a crosshead speed of 1.0 mm/minute. One-way ANOVA followed by Tukey's HSD test (alpha = 0.05) was done. SEM observations of the dentin surface after the testswere also conducted. Dentin bond strength ranged from 9.5 +/- 2.2 to 14.0 +/- 2.4 MPa for AP, 7.3 +/- 2.2 to 12.2 +/- 3.1 MPa for AQ, 10.0 +/- 3.5 to 16.3 +/- 2.4 MPa for FB, 11.4 +/- 1.5 to 16.3 +/- 1.2 MPa for GB, 14.2 +/- 3.4 to 15.1 +/- 3.0 MPa for OF and 11.5 +/- 2.4 to 15.9 +/- 2.2 MPa for XE. Except for OF, no significant differences were found among the 2 to 10 minute delayed placement groups for the systems used. Significant lower bond strengths were obtained for the immediate placement groups except for OF. From SEM observations, cohesive failure of the dentin surface was more pronounced with the longer delay in placement. The data suggest that delayed composite placement over the cured adhesives are suggested for optimum dentin bond strength of single-application self-etch adhesive systems.
机译:这项研究检查了固化粘合剂上的复合材料放置延迟与几种单次应用自蚀刻粘合剂系统的牙本质粘合强度之间的关系。所使用的粘合剂体系/树脂复合材料组合为:Adper Prompt L-Pop / Filtek Z250(AP),AQ Bond Plus / Metafil C(AQ),Fluoro Bond Shake One / Beautifil(FB),G-Bond / Solare(GB) ,单键Bond F Plus / Palfique Estelite(OF),Xeno IICF Bond / Xeno CF(XE)。将牛下颌切牙安装在自固化树脂中,并用#600 SiC湿磨以暴露阴唇牙本质。根据各制造商的说明施加粘合剂,并且在粘合剂的光照射后1、2、5和10分钟立即将树脂糊剂凝结到模具中(o4×2mm)。每个测试组将十个样品存储在37摄氏度的水中24小时,然后以1.0毫米/分钟的十字头速度进行剪切测试。完成单向方差分析,然后进行Tukey的HSD测试(α= 0.05)。测试后还进行了牙本质表面的SEM观察。牙本质粘合强度对于AP为9.5 +/- 2.2至14.0 +/- 2.4 MPa,对于AQ为7.3 +/- 2.2至12.2 +/- 3.1 MPa,对于FB为10.0 +/- 3.5至16.3 +/- 2.4 MPa,对于GB为11.4 +/- 1.5至16.3 +/- 1.2 MPa,对于OF为14.2 +/- 3.4至15.1 +/- 3.0 MPa,对于XE为11.5 +/- 2.4至15.9 +/- 2.2 MPa。除了OF以外,对于使用的系统,在2到10分钟的延迟放置组之间没有发现显着差异。除了OF以外,立即放置组的粘结强度明显降低。从SEM观察,随着放置时间的延长,牙本质表面的内聚破坏更加明显。数据表明,建议将复合材料延迟放置在固化的粘合剂上,以实现单次应用自蚀刻粘合剂体系的最佳牙本质粘合强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号