...
首页> 外文期刊>Revue de chirurgie orthopedique et traumatologique >Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker IV). A model study [étude comparative biomécanique de l'ostéosynthèse par plaque vissée versus vis dans les fractures du plateau tibial médial de type Schatzker 4]
【24h】

Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker IV). A model study [étude comparative biomécanique de l'ostéosynthèse par plaque vissée versus vis dans les fractures du plateau tibial médial de type Schatzker 4]

机译:胫骨平台内侧骨折中板螺钉和螺钉固定的生物力学比较(Schatzker IV)。模型研究[在Schatzker 4型胫骨平台内侧骨折中,螺钉钢板与螺钉进行骨力学合成的生物力学比较研究]

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction: The objective of this biomechanical study was to compare the respective efficiency of plate-screw fixation and screw fixation in an experimental model of a Schatzker type IV fracture. Hypothesis: Screw fixation and plate fixation have a similar load to failure. Materials and methods: This study compares the stability of Schatzker type IV medial tibial plateau fractures fixed with either three 6.5. mm cancellous bone screws with a 16. mm threaded segment or with six-holed buttress T plate-screw system. A Schatzker type IV fracture was modeled on an artificial bone model. In a first group of 10 fracture models, following the anatomical reduction, fractures were stabilized with screws with washers. In the second group of 10 fracture models, fractures were stabilized with T plate. After fixation, ascending axial compression was applied on bone models (Instron machine). Results: Load bearing capacity was 1397.6 ± 194.4 in group I and 2153.2 ± 204.4 in group II. The difference between two groups were statistically significant (p<0.001). Discussion: According to this result, experimental load bearing of bone models indicates that plate-screw fixation system has a significantly higher stabilization capacity than fixation with three screws alone. Our hypothesis was not confirmed. In order to maintain anatomical repositioning, the plate-screw system is a more stable fixation method than the screw in medial tibial plateau fractures of Schatzker type IV.
机译:简介:这项生物力学研究的目的是在Schatzker IV型骨折的实验模型中比较板螺钉固定和螺钉固定的效率。假设:螺钉固定和板固定的失效载荷相似。材料和方法:本研究比较了用三个6.5固定的Schatzker IV型胫骨内侧平台骨折的稳定性。毫米的松质骨螺钉,带16毫米的螺纹段或六孔支撑T形板螺钉系统。在人造骨模型上模拟了Schatzker IV型骨折。在第一个10组骨折模型中,在解剖复位后,用带垫圈的螺钉固定骨折。在第二组的10个骨折模型中,用T板稳定骨折。固定后,在骨骼模型(Instron机)上施加轴向轴向压力。结果:第一组的负荷能力为1397.6±194.4,第二组的负荷能力为2153.2±204.4。两组之间的差异具有统计学意义(p <0.001)。讨论:根据该结果,骨骼模型的实验负载表明,板螺钉固定系统比单独使用三个螺钉固定具有更高的稳定能力。我们的假设尚未得到证实。为了保持解剖位置的重新定位,板螺钉系统比IV型Schatzker胫骨平台内侧骨折更稳定的固定方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号