首页> 外文期刊>Russian Journal of Nondestructive Testing >Comparing Efficiency Characteristics of the Digital and Analogue Techniques for Radiation Detection in Systems of Radiation Thickness Measurements
【24h】

Comparing Efficiency Characteristics of the Digital and Analogue Techniques for Radiation Detection in Systems of Radiation Thickness Measurements

机译:辐射厚度测量系统中辐射检测的数字和模拟技术的效率特性比较

获取原文
获取原文并翻译 | 示例
           

摘要

The paper is devoted to selection of optimized techniques for detecting radionuclide radiation in testing objects with large thickness variations. We have drawn up and analyzed an adequate model describing formation of an informative signal in the presence of an inertial processing stage which is characterized by an instrumental "dead" time that cannot be extended. Boundary values of the radiation thickness and radiation intensity have been determined for selecting the digital or analogue (current) detection technique. A method has been developed to compensate fully for the systematic component in the flux intensity error caused by the instrumental dead time. With a view to testing objects with notable variations in the thickness, a method has been suggested for selective measurements of the radiation intensity.
机译:本文致力于选择优化技术来检测厚度变化较大的物体时的放射性核素辐射。我们已经绘制并分析了一个适当的模型,该模型描述了在惯性处理阶段的存在下信息信号的形成,该阶段的特点是无法延长仪器的“死”时间。已经确定了辐射厚度和辐射强度的边界值,以选择数字或模拟(电流)检测技术。已经开发出一种方法来完全补偿由仪器死区时间引起的通量强度误差中的系统成分。为了测试厚度有显着变化的物体,已经提出了一种用于选择性测量辐射强度的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号