首页> 外文期刊>Retina >Fibrovascular Membrane Removal Using a High-Performance 25-Gauge Vitreous Cutter
【24h】

Fibrovascular Membrane Removal Using a High-Performance 25-Gauge Vitreous Cutter

机译:使用高性能25规格玻璃体切割器去除纤维膜

获取原文
获取原文并翻译 | 示例
           

摘要

Removal of proliferativemembranes from the retina is essential for treating proliferative vitreoreti-nopathy but has remained difficult.1 Membrane del-amination with several scissors or special instruments, maneuvered with one hand or bimanually, have been used.2 However, these techniques are both time-consuming and invasive. Therefore, recently, some vit-rectomy surgeons have preferred to remove the fibrovascular membrane using only a 25-gauge vitrectomy cutter with no scissors during vitrectomy. However, each vitreous cutter has its unique performance characteristics which depend on its cutting cycle, flow rate, and duty cycle. To remove fibrovascular membranes more effectively and safely, we have applied a surgical technique using a 25-gauge vitreous cutter with the high flow rate and high duty cycle.
机译:从视网膜上去除增生膜对于治疗增生性玻璃体视网膜病变至关重要,但仍然很困难。1已经使用了几把剪刀或专用工具,用一只手或双手进行过的膜脱氨处理。2但是,这些技术都是同时使用的消耗性和侵入性。因此,最近,一些玻璃体切除术的外科医生更喜欢在玻璃体切除术中仅使用25号玻璃体切除术切割器而无需剪刀来切除纤维血管膜。但是,每个玻璃体切割器都有其独特的性能特征,这取决于其切割周期,流速和占空比。为了更有效,更安全地去除纤维血管膜,我们采用了一种外科手术技术,该技术采用25口玻璃体切割器,具有高流量和高占空比。