首页> 外文期刊>Retina >Exercise-induced acute changes in systolic blood pressure do not alter choroidal thickness as measured by a portable spectral-domain optical coherence tomography device
【24h】

Exercise-induced acute changes in systolic blood pressure do not alter choroidal thickness as measured by a portable spectral-domain optical coherence tomography device

机译:运动引起的收缩压急性变化不会改变脉络膜厚度,如通过便携式光谱域光学相干断层扫描设备测量的

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE:: To measure choroidal thickness in patients manifesting an acute change in systemic arterial blood pressure using a portable spectral-domain optical coherence tomography device (iVue). METHODS:: Fifteen patients (15 eyes) undergoing cardiac exercise stress testing were scanned using a portable spectral-domain optical coherence tomography system (iVue). Two scan protocols were used: cross line scan for measuring choroidal thickness and the retina map scan to measure retinal thickness. Each patient was scanned before and within 3 minutes after the stress test. Blood pressure was measured at the same time as the acquisition of the scans. Choroidal thickness was measured from the posterior edge of the retinal pigment epithelium to the choroid-sclera junction at 500-μm intervals up to 1,000 μm temporal and nasal to the fovea. Retinal thickness was measured by an automated software. All choroidal thickness measurements were performed by two independent observers. RESULTS:: Fifteen patients (15 eyes) with a mean age of 60.6 (±10.4 years) were scanned. There was a significant increase in systolic but not diastolic pressure after stress testing (P < 0.05). The mean choroidal thickness measurements showed no significant difference before and after exercise stress testing (P > 0.05). In addition, there was no significant difference in retinal thickness before and after stress testing measurements (P > 0.05). CONCLUSION:: There was no change in choroidal thickness or retinal thickness, despite an acute change in the systemic systolic blood pressure induced by exercise.
机译:目的:使用便携式光谱域光学相干断层扫描设备(iVue)测量表现出系统性动脉血压急性变化的患者的脉络膜厚度。方法:使用便携式光谱域光学相干断层扫描系统(iVue)对接受心脏运动压力测试的15例患者(15眼)进行了扫描。使用了两种扫描方案:用于测量脉络膜厚度的交叉线扫描和用于测量视网膜厚度的视网膜图扫描。在压力测试之前和之后的3分钟内对每个患者进行扫描。在获取扫描数据的同时测量血压。从视网膜色素上皮的后边缘到脉络膜-巩膜交界处的脉络膜厚度以500μm的间隔进行测量,直至颞和鼻中凹分别从1,000μm处测量。视网膜厚度通过自动化软件测量。所有脉络膜厚度的测量均由两名独立的观察员进行。结果:15例患者(15眼)的平均年龄为60.6(±10.4岁)。压力测试后,收缩压显着增加,但舒张压没有显着增加(P <0.05)。脉络膜厚度的平均测量结果显示运动压力测试前后无显着差异(P> 0.05)。此外,在进行压力测试之前和之后,视网膜厚度没有显着差异(P> 0.05)。结论:尽管运动引起的全身收缩压急剧变化,脉络膜厚度或视网膜厚度也没有变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号