首页> 外文期刊>Remote Sensing of Environment: An Interdisciplinary Journal >A method for operational calibration of AVHRR reflective time series data
【24h】

A method for operational calibration of AVHRR reflective time series data

机译:一种AVHRR反射时间序列数据的操作校准方法

获取原文
获取原文并翻译 | 示例
           

摘要

We have developed an automatic method to monitor the AVHRR instrument sensitivity over time in the short-wave reflective channels to ensure that trends in the data series obtained by this instrument are real and not sensor artefacts. Our radiometric calibration method uses the Multivariate Alteration Detection (MAD) algorithm to statistically select invariant features over land areas from multiple image-pairs that are compared to assess changes in the instrument's calibration. This method requires no a priori regional knowledge and is globally applicable. A calibrated time series from Pseudo-Invariant Features located in central Australia are shown to have long-term trends removed. The resulting MAD-based calibration has a root mean squared error of similar to 5-6% for both channels 1 and 2 and is in alignment with other approaches. Crown Copyright (C) 2007 Published by Elsevier Inc. All rights reserved.
机译:我们已经开发了一种自动方法,可以在短波反射通道中随时间监视AVHRR仪器的灵敏度,以确保通过该仪器获得的数据序列的趋势是真实的,而不是传感器伪像。我们的辐射定标方法使用多元变化检测(MAD)算法,从多个图像对中统计选择陆地区域的不变特征,然后对它们进行比较以评估仪器定标的变化。该方法不需要先验区域知识,并且在全球范围内都可应用。来自澳大利亚中部的伪不变特征的校准时间序列显示已消除了长期趋势。所得的基于MAD的校准对于通道1和2均具有均方根均方根误差,类似于5-6%,并且与其他方法一致。 Crown版权所有(C)2007,由Elsevier Inc.保留。保留所有权利。