PURPOSE: To evaluate a breath-hold fast spin-echo (SE) technique for T2-weighted magnetic resonance (MR) imaging of liver lesions. MATERIALS AND METHODS: A fast SE technique was developed that enabled six sections to be imaged per 16-second breath hold with a single echo. Resulting images were compared with those obtained with the first echo of a conventional dual-echo T2-weighted SE sequence (16 minutes 55 seconds for 18 sections). Thirty-one patients with malignant focal hepatic lesions were studied prospectively. The images were compared quantitatively and qualitatively. RESULTS: Quantitatively, the contrast and contrast-to-noise ratios for the fast SE images were 20% +/- 5 and 19% +/- 8 greater, respectively, than those for the conventional T2-weighted SE images of the 54 representative lesions. Qualitatively, fast SE images had less image artifact, enabled comparable or better lesion sizing, and greatly improved depiction of extrahepatic structures compared with conventional T2-weighted SE images.CONCLUSION: The fast SE technique with breath holding provides diagnostically useful liver images in a greatly decreased acquisition time.
机译:目的:评估屏气快速自旋回波(SE)技术用于肝脏病变的T2加权磁共振(MR)成像。材料和方法:开发了一种快速的SE技术,使每16秒钟屏住呼吸时可以用一次回波对六个部分成像。将所得图像与常规双回波T2加权SE序列的第一个回波获得的图像进行比较(18个部分16分钟55秒)。前瞻性研究了31例恶性局灶性肝病灶患者。对图像进行定量和定性比较。结果:定量地,快速的SE图像的对比度和对比度噪声比分别比54个代表的传统T2加权SE图像分别高20%+/- 5和19%+/- 8病变。从质量上讲,与常规的T2加权SE图像相比,快速SE图像具有更少的图像伪影,可比的病灶尺寸或更好的病灶尺寸,并大大改善了肝外结构的描述。结论:屏气的快速SE技术在很大程度上可提供诊断有用的肝脏图像减少采集时间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号