首页> 外文期刊>Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science >Chemical characterization of selected metals by X-ray fluorescence method in particulate matter collected in the area of Krakow, Poland
【24h】

Chemical characterization of selected metals by X-ray fluorescence method in particulate matter collected in the area of Krakow, Poland

机译:通过X射线荧光法对波兰克拉科夫地区收集的颗粒物中的某些金属进行化学表征

获取原文
获取原文并翻译 | 示例
           

摘要

This study presents the results of year long (2007-2008) particulate matter collecting campaigns. The three particle size fractions of particulate matter were collected in Krakow, Poland. Fine fraction consists of particles of a diameter below 2.5 mu m, medium is between 2.5 and 8 mu m and coarse fraction contains particles above 8 mu m. Elemental concentrations were evaluated for each sample. Following elements were measured by EDXRF method: K, Ca, Ti, Cr, Mn, Fe, Cu, Zn, Br, and Pb. During each sampling campaign meteorological parameters such as temperature, wind speed, wind direction, humidity were taken from the same place. The highest values of mass particulate matter showed results from January 2008 and April 2008. These were about 14 mu g/m(3) for fine fraction, 8 mu g/m(3) for medium and 16 mu g/m(3) for coarse fraction. The lowest values were observed in May 2007, they were 4,6,6 mu g/m(3), respectively. During the winter season the wind speed was low and particulate matter remained in the air in high concentrations. In May 2007 the speed of wind was higher, reaching 2-3 m/s. PM was blown away from the city from the direction of N-W. Measured concentrations of elements were low, they were below permissible values specified by EU. The coarse fraction concentrations of Ca, Mn, and Fe were higher and characterized by the same trend. These samples were collected when the wind speed was low and its direction was from south-east. As concentrations of Cr, Cu, and Zn were low, these elements did not come from the south-east direction of Krakow. Concentration of Br correlates to the concentration of Pb. It suggests that they came from the same source (vehicles fuels burning).
机译:这项研究提出了为期一年(2007-2008年)的颗粒物收集活动的结果。在波兰的克拉科夫收集了三个颗粒大小的颗粒物。细颗粒由直径小于2.5微米的颗粒组成,介质介于2.5和8微米之间,粗颗粒则包含大于8微米的颗粒。评估每个样品的元素浓度。通过EDXRF方法测量以下元素:K,Ca,Ti,Cr,Mn,Fe,Cu,Zn,Br和Pb。在每次采样活动中,气象参数如温度,风速,风向,湿度均取自同一地点。质量颗粒物的最高值显示了从2008年1月到2008年4月的结果。细粒分数约为14μg / m(3),中等分数约为8μg / m(3),而16μg/ m(3)粗略的分数。在2007年5月观察到最低值,分别为4,6,6μg / m(3)。在冬季,风速低,颗粒物以高浓度残留在空气中。 2007年5月,风速更高,达到2-3 m / s。 PM从西北方向吹离城市。元素的测得浓度很低,低于欧盟规定的允许值。 Ca,Mn和Fe的粗颗粒浓度较高,并且具有相同的趋势。当风速低并且风向是从东南方向时,收集这些样本。由于Cr,Cu和Zn的浓度较低,因此这些元素并非来自克拉科夫的东南方向。 Br的浓度与Pb的浓度相关。这表明它们来自同一来源(车辆燃料燃烧)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号