Angular dependence of the luminance and contrast in medical monochrome liquid crystal displays.

机译:医用单色液晶显示器中亮度和对比度的角度依赖性。

获取原文
获取原文并翻译 | 示例
           

摘要

Active-matrix liquid crystal displays (AMLCDs) are light-modulating devices that generate images by differentially transmitting a nearly uniform luminous field provided by a backlight. While emissive displays exhibit a quasi-Lambertian emission with almost constant contrast at off-normal viewing, the anisotropy of the electro-optic effect that controls light transmission in AMLCDs causes a pixel luminance that varies, sometimes strongly, with viewing angle. These variations are not identical for all gray levels and can eventually cause grayscale inversions. In this paper, we measured the luminance emission of a monochrome medical AMLCD, a medical cathode-ray tube monitor, and a color desktop AMLCD, using a collimated photopic probe positioned on a manual rotation arm, and a research radiometer with automatic readout. The probe measures luminance with a small acceptance angle and provides optical shielding from emissions at other viewing directions that contaminate the readings. We obtained luminance response curves versus angle in the vertical, horizontal and at 45 degrees diagonal directions. The display systems were calibrated to reflect the DICOM Part 3.14 standard grayscale display function (GDF) when measured using the manufacturer's probe and software tools. We analyzed the measurements at different viewing directions with respect to their departure from the GDF by computing the normalized contrast (deltaL/L) as a function of the DICOM just-noticeable difference index. Although cathode-ray tubes are known to be quasi-Lambertian emitters, the luminance at normal viewing is higher than the luminance observed at large angles. This decrease in luminance is however proportionally similar for all gray levels, resulting in a relatively flat contrast response for all angles. In addition to being more pronounced, the angular variation in AMLCDs does not follow the same profile at different intensities with the subsequent variation in the achieved display contrast. The changes due to off-normal viewing are substantial at large angles in the horizontal and vertical directions, and much worse in the diagonal viewing directions.
机译:有源矩阵液晶显示器(AMLCD)是一种光调制设备,通过差分传输背光提供的几乎均匀的光场来生成图像。虽然发光显示器在非正常观看时显示出具有几乎恒定对比度的准朗伯发射,但是控制AMLCD中光透射的电光效应的各向异性会导致像素亮度随视角而变化,有时变化很大。这些变化并非在所有灰度级上都相同,最终可能导致灰度反转。在本文中,我们使用定位在手动旋转臂上的准直光学探针和具有自动读数的研究辐射计,测量了单色医用AMLCD,医用阴极射线管监视器和彩色台式AMLCD的发光强度。探头以较小的接收角测量亮度,并提供光学屏蔽,以防止其他观察方向的发射污染读数。我们获得了亮度响应曲线与垂直,水平和对角线45度角的关系。使用制造商的探头和软件工具进行测量时,显示系统经过校准以反映DICOM Part 3.14标准灰度显示功能(GDF)。我们通过计算归一化对比度(deltaL / L)作为DICOM显着差异指数的函数,分析了在不同观看方向上与GDF偏离的测量结果。尽管已知阴极射线管是准朗伯发射器,但是正常观察时的亮度高于在大角度观察到的亮度。然而,对于所有灰度级,这种亮度降低成比例地相似,从而导致对于所有角度而言相对平坦的对比度响应。除了更明显之外,AMLCD的角度变化在不同的强度下不会遵循相同的轮廓,从而导致显示对比度发生后续变化。由于偏离法线观看的变化在水平和垂直方向上在大角度上是相当大的,而在对角线观看方向上则更糟。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号