首页> 外文期刊>Canadian Journal of Dietetic Practice and Research >Air displacement plethysmography for fat-mass measurement in healthy young women.
【24h】

Air displacement plethysmography for fat-mass measurement in healthy young women.

机译:空气体积描记法用于健康年轻女性的脂肪质量测量。

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: Dual energy X-ray absorptiometry (DXA) and air displacement plethysmography (ADP) are commonly used to assess body composition. Accurate body fat measures are valuable in a variety of populations. Because DXA, the reference standard, is expensive and labour-intensive, determining whether these two methods are interchangeable is important. Methods: Forty-five female undergraduate students aged 21 to 33 with body mass indexes of 18.3 to 28.6 kg/m2 were recruited from the University of Guelph. Each participant underwent one full-body DXA scan and one ADP assessment, to determine total percent fat mass (%FM). Results: The Pearson's correlation between %FMDXA (27.1+or-4.8) and %FMADP (26.1+or-5.5) indicated good association (r=0.88, p<0.01). While Bland-Altman analysis revealed no systematic bias between the two methods (R2=0.07, p=0.08), large intraindividual variation occurred (95% confidence interval: -5.86% to 4.11%); this was related to height, weight, body-surface area, and lung volume. Conclusions: The two methods were significantly correlated. Mean %FM was not significantly different and no systematic bias between methods was observed. These findings indicate that ADP and DXA may be used interchangeably for determining %FM at the group level in healthy young women; a large intraindividual variation between the methods precludes interchangeability at the individual level.Digital Object Identifier http://dx.doi.org/10.3148/72.2.2011.85
机译:目的:双能X线骨密度仪(DXA)和空气体积体积描记法(ADP)通常用于评估人体成分。准确的体内脂肪测量对各种人群都很有价值。由于参考标准DXA昂贵且劳动强度大,因此确定这两种方法是否可互换非常重要。方法:从圭尔夫大学(University of Guelph)招募了45名21至33岁,体重指数为18.3至28.6 kg / m 2 的女大学生。每个参与者进行一次全身DXA扫描和一项ADP评估,以确定总脂肪质量百分比(%FM)。结果:%FM DXA (27.1 + or-4.8)和%FM ADP (26.1 + or-5.5)之间的Pearson相关性表明相关性良好(r = 0.88,p <0.01)。 Bland-Altman分析显示两种方法之间没有系统偏差(R 2 = 0.07,p = 0.08),但出现了较大的个体差异(95%置信区间:-5.86%至4.11%);这与身高,体重,体表面积和肺容量有关。结论:两种方法之间存在显着相关性。平均%FM没有显着差异,并且未观察到方法之间的系统偏差。这些发现表明,在健康的年轻女性中,ADP和DXA可以互换使用来确定组水平的%FM。这些方法之间的巨大个体差异使得在个体级别上的互换性无法实现。数字对象标识符http://dx.doi.org/10.3148/72.2.2011.85

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号