HPLC combined with ICP-MS for the determination of trace amounts of rare earth impurities in high-purity La_2O_3 by using 2-ethylhexyl hydrogen-2-ethylhexylphosphonate resin as a stationary phase

机译:HPLC-ICP-MS联用2-乙基己基氢-2-乙基己基膦酸酯树脂测定高纯La_2O_3中的痕量稀土杂质

获取原文
获取原文并翻译 | 示例
           

摘要

A new method for the determination of trace rare earth impurities in high-purity La2O3 by HPLC com-bined with ICP-MS is proposed. The chromatographic re-tention behavior of La and Ce in HPLC was studied with 2-ethylhexyl-hydrogen-2-ethylhexylphosphonate (P507) resin as the stationary phase and inorganic acid (HNO3) as the mobile phase. The effects of acidity of the mobile phase, flow rate of eluent and- column oven temperature on the separation of La and Ce were investigated in detail. The results of the effect of different ratios of La / Ce showed that a favorable separation of La and Ce could be obtained easily and rapidly with the method presented. Compared with the conventional open column method, the proposed separation system shows a good performance with regard to short separation time, low reagent consumption, and simple operation. The method has been applied to the analysis of real samples of high-purity La203 with satisfactory results.
机译:提出了一种HPLC-ICP-MS联用法测定高纯La2O3中微量稀土杂质的新方法。以2-乙基己基氢-2-乙基己基膦酸酯(P507)树脂为固定相,以无机酸(HNO3)为流动相,研究了La和Ce在HPLC中的色谱保留行为。详细研究了流动相的酸度,洗脱液的流速和柱箱温度对La和Ce分离的影响。 La / Ce不同比例的影响结果表明,采用上述方法可以轻松,快速地实现La和Ce的良好分离。与传统的开放式色谱柱方法相比,所提出的分离系统具有较短的分离时间,较低的试剂消耗和简单的操作方面的良好性能。该方法已用于高纯度La2O3真实样品的分析,结果令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号