...
首页> 外文期刊>Eye & contact lens >Corneal thickness change induced by dozing while wearing hydrogel and silicone hydrogel lenses.
【24h】

Corneal thickness change induced by dozing while wearing hydrogel and silicone hydrogel lenses.

机译:戴水凝胶和硅胶水凝胶镜片时打do睡会导致角膜厚度变化。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: The physiologic effects on the cornea of dozing while wearing contact lenses were assessed by using central corneal swelling as an index in relation with lens oxygen transmissibility (Dk/t). METHODS: Two hydrogel lens materials (nelfilcon A and etafilcon A) with a power of -0.50 diopters (D) and three silicone hydrogel lens materials (galyfilcon A, senofilcon A, and lotrafilcon A) with a power of -0.50 D were studied on 16 eyes of eight subjects with no previous experience of contact lens wear and no ocular disease. The subjects wore the lenses for seven continuous hours with their eyelids closed for 1 hour after the first 3 hours of lens wear to simulate a dozing condition. Corneal thickness was measured with a specular microscope with a built-in pachometer (Topcon SP-2000P). The same measurement was performed for the non-lens-wearing eyes as the control. RESULTS: Swelling rates immediately after dozing were 4.8%+/-1.4% for nelfilcon A, 5.2%+/-1.7% for etafilcon A, 2.8%+/-1.2% for galyfilcon A, 1.9%+/-0.8% for senofilcon A, and 1.5%+/-1.6% for lotrafilcon A. The swelling rates for the two hydrogel lenses were significantly higher (P<0.001) than that for the control (1.8%+/-1.5%), and the differences remained significant after 3 hours. Conversely, none of the three silicone hydrogel lenses showed a significant difference (P>0.05) compared to the control at any measurement. CONCLUSIONS: The results indicate that dozing with silicone hydrogel lens wear causes clearly fewer intense physiologic effects in oxygen performance than dozing with hydrogel lens wear.
机译:目的:通过使用角膜中央的肿胀作为与镜片氧气透过率(Dk / t)相关的指标,评估戴隐形眼镜对on睡角膜的生理效应。方法:研究了两种具有-0.50屈光度(D)的水凝胶镜片材料(nelfilcon A和etafilcon A)和三种具有-0.50 D的屈光度的有机硅水凝胶镜片材料(galyfilcon A,senofilcon A和lotrafilcon A)。八位受试者的16只眼没有戴隐形眼镜的经验,也没有眼部疾病。戴眼镜的前3个小时,受试者连续7个小时戴眼镜,并闭上眼睑1个小时,以模拟打zing情况。角膜厚度用带有内置转速计的镜面显微镜(Topcon SP-2000P)测量。对于非配戴眼镜的眼睛,进行与对照组相同的测量。结果:zing虫后立即溶胀率为nelfilcon A为4.8%+ /-1.4%,etafilcon A为5.2%+ /-1.7%,galyfilcon A为2.8%+ /-1.2%,senofilcon为1.9%+ /-0.8% A和lotrafilcon A的1.5%+ /-1.6%。两个水凝胶镜片的溶胀率(P <0.001)显着高于对照组(1.8%+ /-1.5%),并且差异仍然显着3小时后。相反,在任何测量下,与对照相比,三个有机硅水凝胶镜片均未显示出显着差异(P> 0.05)。结论:结果表明,与戴水凝胶镜片配镜打do相比,戴硅胶水凝胶镜片配镜打do对氧气性能的强烈生理影响明显更少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号