...
【24h】

Could clinical ultrasound improve the fitting of spinal orthosis for the patients with AIS?

机译:临床超声能否改善AIS患者的脊柱矫形器的适应性?

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose This study aimed to improve the effectiveness of orthotic treatment for the patients with AIS using the threedimensional clinical ultrasound (3D CUS) method in which the optimal location of pressure pad of spinal orthosis was determined with the assistance of ultrasound image analysis. Methods By means of 3D CUS method, the spinous process angle (SPA) could be traced and used as a clinical parameter to estimate the Cobb's angle in order to determine the location of pressure pad. Twenty-one patients (test group) and 22 patients (control group) were recruited to the ultrasound-assisted fitting method and the conventional fitting method, respectively. All the measurements were done by a blinded observer. Results The intra-rater reliability of using 3D CUS to measure SPA was found >0.9 >ICC (3,3) = 0.91, p<0.05]. In the test group, 13 out of 21 patients were required to adjust the location of pressure pad in order to achieve the largest curvature correction. The mean immediate in-brace corrections (Cobb's angle measured from radiographs) of the test group (mean thoracic curve correction: 10.3°, mean lumbar curve correction: 10.1°) were found significantly higher (p<0.005) than that of the control group (mean thoracic curve correction: 4.6°, mean lumbar curve correction: 6.0°). The results showed that the ultrasound-assisted fitting method of spinal orthosis was effective and beneficial to 62 % of the patients in this study. Conclusions The 3D CUS could be considered as an effective, non-invasive and fast assessment method to scoliosis, especially in enhancing the effectiveness of orthotic treatment and its applications could also be further extended to other spinal deformities.
机译:目的本研究旨在通过三维临床超声(3D CUS)方法提高对AIS的矫形治疗的有效性,该方法通过超声图像分析确定脊柱矫正器的最佳压垫位置。方法借助3D CUS方法,可以追踪棘突角(SPA)并作为临床参数来估计Cobb角,从而确定压垫的位置。分别招募21例患者(测试组)和22例患者(对照组)进行超声辅助拟合方法和常规拟合方法。所有的测量都是由一个盲目的观察者完成的。结果发现使用3D CUS测量SPA的评分者内信度> 0.9> ICC(3,3)= 0.91,p <0.05]。在测试组中,需要21名患者中的13名患者调整压力垫的位置,以实现最大的曲率矫正。发现测试组的平均即刻矫正术(从X线照片测量的Cobb角)(平均胸廓曲线矫正:10.3°,平均腰椎弯曲矫正:10.1°)显着高于对照组(p <0.005) (平均胸廓曲线矫正:4.6°,平均腰椎曲线矫正:6.0°)。结果表明,本研究中超声辅助的脊柱矫形器拟合方法有效且有益于62%的患者。结论3D CUS可被视为脊柱侧弯的一种有效,无创且快速的评估方法,尤其是在增强矫形治疗的有效性方面,其应用还可以进一步扩展到其他脊柱畸形。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号