This study evaluated the in vitro response of murine macrophages to clinically relevant polyethylene particles from two grades of UHMWPE at varying volume doses. Clinically relevant UHMWPE wear debris was generated in vitro using a tri-pin-on-disc tribometer. The debris was observed using a scanning electron microscope and analysed by image analysis. There was no significant difference in the wear rates of the two grades of UHMWPE. Analysis of the wear debris showed that GUR 415HP produced a higher percentage of mass of debris in the submeter size range compared to GUR 1120. The wear debris was co-cultured with C3H murine peritoneal macrophages at particle volume (&mgr;m(3)): cell number ratios of 100 :1, 50 :1, 10 :1 and 1 :1 for both grades of UHMWPE and additionally at 0.5 :1 and 0.1 :1 for grade GUR 415HP. The secretion of TNF-alpha was determined by ELISA. Significantly elevated levels of TNF-alpha were secreted at 100 :1 ratio when macrophages were challenged with wear debris from GUR 1120 and at 10 :1 and 1 :1 for debris from GUR 415HP. The results suggested that the greater percentage mass of debris in the submicrometer size range from GUR 415HP lead to a substantial increase in biological activity for this grade of UHMWPE on a volume for volume basis when compared with GUR 1120.
机译:这项研究评估了鼠巨噬细胞对来自不同浓度剂量的两个等级的UHMWPE的临床相关聚乙烯颗粒的体外反应。使用三针盘式摩擦计在体外产生了临床相关的UHMWPE磨损碎片。使用扫描电子显微镜观察碎片,并通过图像分析进行分析。两种级别的UHMWPE的磨损率没有显着差异。对磨损碎片的分析表明,与GUR 1120相比,GUR 415HP在亚米级尺寸范围内产生的碎屑质量百分比更高。磨损碎片与C3H鼠腹膜巨噬细胞以颗粒体积(&mgr; m(3))共培养。对于两种等级的UHMWPE:100:1、50:1、10:1和1:1的::单元数目比,对于GUR 415HP,分别为0.5:1和0.1:1。通过ELISA确定TNF-α的分泌。当巨噬细胞受到来自GUR 1120的磨损碎片攻击时,以100:1的比例分泌显着升高的TNF-α,而来自GUR 415HP的碎片则以10:1和1:1分泌。结果表明,与GUR 1120相比,在GUR 415HP的亚微米尺寸范围内更大的碎片质量百分比导致这种级别的UHMWPE的生物活性大大提高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号