首页> 外文期刊>Engineering failure analysis >Failure analysis of spiral finned tube on the economizer
【24h】

Failure analysis of spiral finned tube on the economizer

机译:省煤器螺旋翅片管的失效分析

获取原文
获取原文并翻译 | 示例
           

摘要

This article describes the results of an investigation about the failure of spiral finned tube on a newly designed and retrofitted low pressure economizer in a 300 MW pulverized-coal-flred power plant. In order to find out the failure causes and to suggest preventive measures, phase compositions and macrostructure of the tube metal surface were investigated by X-Ray Diffraction and Scanning Electron Microscope equipped with energy dispersive X-Ray spectroscopy micro-analysis. The results show that the failure was principally owing to comprehensive multiphase erosion, an interaction of the fly ash wearing, flue gas washing and sulfurous acid corrosion. Recommendations are given to minimize such failures.
机译:本文介绍了对300 MW煤粉火电厂新设计和改造的低压省煤器螺旋翅片管故障的调查结果。为了找出故障原因并提出预防措施,采用配备了能量色散X射线光谱微分析的X射线衍射和扫描电子显微镜研究了管金属表面的相组成和宏观结构。结果表明,失效的主要原因是全面的多相腐蚀,粉煤灰磨损,烟道气洗涤和亚硫酸腐蚀的相互作用。给出了建议,以尽量减少此类故障。