首页> 外文期刊>Electrophoresis: The Official Journal of the International Electrophoresis Society >Capillary electrophoresis-inductively coupled plasma-mass spectrometry: A report on technical principles and problem solutions, potential, and limitations of this technology as well as on examples of application.
【24h】

Capillary electrophoresis-inductively coupled plasma-mass spectrometry: A report on technical principles and problem solutions, potential, and limitations of this technology as well as on examples of application.

机译:毛细管电泳-电感耦合等离子体质谱法:有关技术原理和问题解决方案,该技术的潜力和局限性以及应用实例的报告。

获取原文
获取原文并翻译 | 示例
           

摘要

This paper summarizes some basic principles of capillary electrophoresis (CE), inductively coupled plasma-mass spectrometry (ICP-MS), and coupling of both devices. Especially the interfacing is described in detail. A special focus is drawn to various interface developments reported in literature and technical problems, i.e., requirements to the interface setup and respective solutions. Nowadays, typically sheath flow-based interfaces are used. The sheath flow fulfills two requirements of hyphenation, (i) the closing of the electrical circuit of CE and (ii) the feeding of the used nebulizer with an adequate flow rate. In the beginning of CE-ICP-MS coupling predominantly home-made interface-nebulizer constructions were developed and tested for various speciation problems. Now increasingly such laboratory-constructed interfaces are left. Mostly commercial nebulizers are employed being combined with commercially available tee or cross fittings to connect the CE capillary to the electrode, the additional sheath flow, and the nebulizer. Due to the low sample amounts and low flow rates from CE, such nebulizers are typically low-flow nebulizers like, e.g., the microconcentric nebulizer (MCN) and the direct injection nebulizer (DIN). However, there are also reports on couplings using standard Meinhard systems. Still the control and reduction of a siphoning sucting flow and sufficient detection limits are the major problems in hyphenating CE to ICP-MS. Different solutions are reported on these problems and summarized here. Finally numerous applications are reported. Mostly, applications are performed on speciation of selenium, arsenic, metallothionein isoforms, mercury, or cobalt.
机译:本文总结了毛细管电泳(CE),电感耦合等离子体质谱(ICP-MS)以及这两种设备的耦合的一些基本原理。特别是对接口进行了详细描述。特别关注文献和技术问题中报告的各种接口开发,即对接口设置和相应解决方案的要求。如今,通常使用基于鞘流的接口。鞘流满足连字符的两个要求,(i)关闭CE的电路,以及(ii)以足够的流速送入用过的雾化器。在CE-ICP-MS开始之初,主要开发了自制的接口雾化器结构并针对各种形态问题进行了测试。现在越来越多地保留了这种实验室构建的界面。大多数情况下,将商用雾化器与商用三通或十字接头结合使用,以将CE毛细管连接到电极,额外的鞘流和雾化器。由于来自CE的样品量少且流速低,因此此类雾化器通常是低流量雾化器,例如微同心雾化器(MCN)和直接注入雾化器(DIN)。但是,也有关于使用标准Meinhard系统的联轴器的报道。在将CE连接到ICP-MS时,主要问题仍然是控制和减少虹吸抽吸流量以及足够的检测极限。报告了有关这些问题的不同解决方案,并在此处进行了总结。最后,报道了许多应用。通常,对硒,砷,金属硫蛋白同工型,汞或钴的形态进行应用。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号