首页> 外文期刊>Investigative radiology >Detection of small metastatic brain tumors: comparison of 3D contrast-enhanced whole-brain black-blood imaging and MP-RAGE imaging.
【24h】

Detection of small metastatic brain tumors: comparison of 3D contrast-enhanced whole-brain black-blood imaging and MP-RAGE imaging.

机译:小型转移性脑瘤的检测:3D对比增强的全脑黑血成像和MP-RAGE成像的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: Early and accurate diagnosis of small metastatic brain tumors may affect outcomes and treatment strategies. For this reason, 3-dimensional (3D) thin-section imaging is preferred. However, with conventional contrast-enhanced (CE) 3D imaging, such as magnetization-prepared rapid gradient echo (MP-RAGE), many visually enhanced vessels may mimic small metastatic tumors, hindering tumor detection. CE black-blood single-slab 3D turbo-spin echo imaging (BB-ssTSE) was recently developed, which uses variable refocusing flip angles and flow-sensitizing gradient schemes, to enhance metastatic brain tumors while selectively suppressing blood vessels. The purpose of this work was to investigate the efficiency of the proposed CE BB-ssTSE in detecting small metastatic brain tumors as compared with conventional MP-RAGE. MATERIALS AND METHODS: Numerical comparisons of MP-RAGE and BB-ssTSE were performed by simulation studies to investigate the signal/contrast behaviors of flowing blood and stationary CE tumors. For in vivo studies, we enrolled 35 patients (18 women; mean age, 58.1 years) with breast or lung cancer who underwent brain magnetic resonance imaging. After administering a double dose of contrast medium, whole-brain 2-dimensional T1-weighted imaging followed by high-resolution isotropic 3D BB-ssTSE and MP-RAGE was performed at 3.0 T. Two reviewers independently evaluated the presence of metastatic brain tumors using: (1) MP-RAGE; (2) BB-ssTSE; and (3) MP-RAGE + BB-ssTSE sequentially in 3 review sessions, 2 weeks apart. The lesions were classified by size into 2 groups: large (>/=5 mm) and small (<5 mm). Both reviewers marked all tumors detected at each session. Another reviewer combined the results of the 2 reviewers and compared the detection rates of metastatic brain tumors between BB-ssTSE and MP-RAGE by using follow-up imaging. Intraclass correlation coefficients between the 2 reviewers were measured. RESULTS: Numerical simulations showed that the proposed BB-ssTSE effectively attenuated the signal intensity of flowing blood over the entire echo train, resulting in CE tumor-to-white matter contrast comparable with conventional MP-RAGE. The combined evaluation of MP-RAGE + BB-ssTSE showed 242 tumors in 28 patients. Of these, 153 lesions were <5 mm. MP-RAGE found 111 small metastatic brain tumors, BB-ssTSE found 150, and MP-RAGE + BB-ssTSE found 153. Significantly, more small tumors were detected by BB-ssTSE than MP-RAGE (P = 0.001, Wilcoxon signed-rank test). All large tumors were detected similarly by both MP-RAGE and BB-ssTSE. By combined results for MP-RAGE + BB-ssTSE, sensitivities for detection of small metastatic tumors were 72.5% for MP-RAGE and 98.0% for BB-ssTSE (P < 0.0001, McNemar test). Intraclass correlation coefficients between the 2 reviewers were 0.826 for MP-RAGE and 0.954 for BB-ssTSE. CONCLUSION: Compared with conventional MP-RAGE, the proposed CE BB-ssTSE imaging, which enhances tumors while selectively suppressing blood vessels, leads to significantly better detection of small metastatic brain tumors <5 mm.
机译:目的:早期准确诊断小转移性脑瘤可能会影响预后和治疗策略。因此,首选3维(3D)薄层成像。但是,使用常规的对比增强(CE)3D成像,例如磁化准备的快速梯度回波(MP-RAGE),许多视觉增强的血管可能会模仿小的转移性肿瘤,从而阻碍了肿瘤的检测。最近开发了CE黑血单平面3D涡轮自旋回波成像(BB-ssTSE),该技术使用可变的重新聚焦翻转角和流量敏感梯度方案,以增强转移性脑肿瘤,同时选择性地抑制血管。这项工作的目的是研究与常规MP-RAGE相比,拟议中的CE BB-ssTSE在检测小转移性脑肿瘤中的效率。材料与方法:通过模拟研究对MP-RAGE和BB-ssTSE进行了数值比较,以研究血液流动性和固定性CE肿瘤的信号/对比行为。对于体内研究,我们招募了35例行脑磁共振成像检查的乳腺癌或肺癌患者(18名女性;平均年龄58.1岁)。在给予双倍剂量的造影剂后,在3.0 T下进行全脑二维T1加权成像,然后进行高分辨率的各向同性3D BB-ssTSE和MP-RAGE成像。两位评价员使用以下方法独立评估了转移性脑肿瘤的存在:(1)MP-RAGE; (2)BB-ssTSE; (3)MP-RAGE + BB-ssTSE在3个评估阶段中相继进行,相隔2周。将病变按大小分为两组:大(> / = 5毫米)和小(<5毫米)。两位评价者标记了在每次会议中检测到的所有肿瘤。另一位审稿人结合了两位审稿人的结果,并通过随访成像比较了BB-ssTSE和MP-RAGE之间转移性脑肿瘤的检出率。测量了两个评论者之间的类内相关系数。结果:数值模拟表明,所提出的BB-ssTSE有效地减弱了整个回波序列中流动的血液的信号强度,从而导致了CE肿瘤与白质的对比度可与常规MP-RAGE媲美。 MP-RAGE + BB-ssTSE的联合评估显示28例患者有242例肿瘤。其中153个病灶小于5毫米。 MP-RAGE发现了111个小转移性脑肿瘤,BB-ssTSE发现了150个,MP-RAGE + BB-ssTSE发现了153个。重要的是,BB-ssTSE发现的小肿瘤比MP-RAGE更多(P = 0.001,Wilcoxon标记为-等级测试)。 MP-RAGE和BB-ssTSE相似地检测到所有大肿瘤。通过MP-RAGE + BB-ssTSE的综合结果,检测出小转移性肿瘤的MP-RAGE灵敏度为72.5%,BB-ssTSE灵敏度为98.0%(P <0.0001,McNemar测试)。 2位评价者之间的类内相关系数对于MP-RAGE为0.826,对于BB-ssTSE为0.954。结论:与常规MP-RAGE相比,拟议的CE BB-ssTSE成像增强了肿瘤,同时选择性地抑制了血管,从而显着更好地检测了小于5 mm的小转移性脑肿瘤。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号