Air-source heat pumps for residential heating are more widely used than geothermal heat pumps mainly due to their lower installation costs. Major disadvantages of air-source heat pumps are the decrease of heat output and coefficient of performance (COP), and increase in discharge temperature, towards low outdoor temperatures. In this paper an air-source two-stage heat pump using R410A as the refrigerant was simulated, designed, constructed, and tested at ambient temperatures as low as -30℃ and supply temperatures of up to 50℃ in air and water heating mode. In addition, the system is able to provide sufficient air conditioning in cooling mode (approximately 50-60% of the design heat transfer rate in heating mode). A short summary of an extended literature review is shown as well as a theoretical screening study of the three most promising cycles. Furthermore, the design and test results of a breadboard system and a comparison with commercially available heat pumps are presented. Second law efficiencies of up to 45% could be achieved, resulting in a coefficient of performance (COP) of 2.1 at -30℃ ambient temperature.
机译:用于住宅供暖的空气源热泵比地热热泵使用更广泛,主要是因为它们的安装成本较低。空气源热泵的主要缺点是热量输出减少和性能系数(COP)降低,并且排放温度升高,导致室外温度降低。本文对以R410A为制冷剂的空气源两级热泵进行了模拟,设计,构造和测试,在空气和水加热模式下,环境温度低至-30℃,供应温度高达50℃。此外,该系统能够在制冷模式下提供足够的空调(在制热模式下约为设计传热率的50-60%)。显示了扩展的文献综述的简短摘要,以及对三个最有希望的周期的理论筛选研究。此外,介绍了面包板系统的设计和测试结果,以及与市售热泵的比较。第二定律效率最高可达到45%,因此在-30℃环境温度下的性能系数(COP)为2.1。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号