...
首页> 外文期刊>British Journal of Radiology >A novel approach of dose mapping using a humanoid breast phantom in radiotherapy.
【24h】

A novel approach of dose mapping using a humanoid breast phantom in radiotherapy.

机译:一种在放射治疗中使用人形乳腺幻影进行剂量映射的新方法。

获取原文
获取原文并翻译 | 示例
           

摘要

A study of dose mapping techniques to investigate the dose distribution throughout a planned target volume (PTV) in a humanoid breast phantom exposed to a 6 MV photon beam similar to that of treatment conditions is described. For tangential breast irradiation using a 6 MV accelerator beam, the dose is mapped at various locations within the PTV using thermoluminescent dosemeters (TLDs) and radiographic films. An average size perspex breast phantom with the ability to hold the dosemeters was made. TLDs were exposed after packing them in various locations in a particular slice, as planned by the treatment planning system (TPS). To map the dose relative to the isocenter, films were exposed after tightly packing them in between phantom slices, parallel to the central axis of the beam. The dose received at every location was compared with the given dose as generated by the TPS. The mapped dose in each location in the isocentric slice from superficial to deep region was found to be in close agreement with the TPS generated dose to within +/-2%. Doses at greater depths and distant medial and lateral ends, however, were found to be lower by as much as 9.4% at some points. The mapped dose towards the superior region and closest inferior region from the isocenter was found to agree with those for TPS. Conversely, results for the farthest inferior region were found to be significantly different with a variance as much as 17.4% at some points, which is believed to be owing to the variation in size and shape of the contour. Results obtained from films confirmed this, showing similar trends in dose mapping. Considering the importance of accurate doses in radiotherapy, evaluating dose distribution using this technique and tool was found to be useful. This provides the opportunity to choose a technique and plan to provide optimum dose delivery for radiotherapy to the breast.
机译:描述了一项剂量映射技术的研究,以研究在类似于治疗条件的6 MV光子束下暴露的人形乳腺模型中整个计划目标体积(PTV)的剂量分布。对于使用6 MV加速器束进行切线乳房照射,使用热发光剂量计(TLD)和X射线胶片将剂量映射到PTV的各个位置。制成了具有保持剂量计能力的平均尺寸的有机玻璃乳腺模型。根据治疗计划系统(TPS)的计划,将TLD包装在特定切片中的不同位置后再暴露。为了绘制相对于等中心点的剂量,将胶片紧紧包装在幻影片之间,平行于光束的中心轴,然后曝光。将在每个位置接收的剂量与TPS产生的给定剂量进行比较。发现在同心切片中从浅表到深部的每个位置的映射剂量与TPS产生的剂量非常吻合,误差在+/- 2%之内。然而,发现在更大深度以及远处的内侧和外侧端的剂量在某些点降低了多达9.4%。发现从等中心点到上部区域和最下部区域的映射剂量与TPS剂量一致。相反,发现最下方的区域的结果明显不同,在某些点上的差异高达17.4%,这被认为是由于轮廓尺寸和形状的变化所致。从胶片获得的结果证实了这一点,在剂量分布图中显示了相似的趋势。考虑到精确剂量在放射治疗中的重要性,发现使用这种技术和工具评估剂量分布是有用的。这为选择一种技术和计划提供了机会,以提供最佳的放射治疗剂量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号