首页> 外文期刊>British Journal of Radiology >Radiological parameters and radiation doses of patients undergoing abdomen, pelvis and lumbar spine X-ray examinations in three Nigerian hospitals.
【24h】

Radiological parameters and radiation doses of patients undergoing abdomen, pelvis and lumbar spine X-ray examinations in three Nigerian hospitals.

机译:尼日利亚三所医院接受腹部,骨盆和腰椎X线检查的患者的放射学参数和放射剂量。

获取原文
获取原文并翻译 | 示例
           

摘要

Thermoluminescent dosemeters (TLDs) have been used to measure the entrance surface doses (ESDs) of patients undergoing pelvis, abdomen and lumbar spine diagnostic X-ray examinations in Nigeria. A total of three public hospitals and 171 patients were included in this investigation. The ages of the patients involved were from 40 years to 85 years, while their weights ranged from 64 kg to 73 kg. Mean, median, first and third quartiles of ESDs are reported. The results showed that in most cases, for each of the examinations, the individual ESD values are found to be comparable with, and higher than, those from Ghana and Tanzania, respectively. The mean ESD values are also found to be within the range of mean ESD values that have been previously been reported from countries outside Africa. When compared with the European Community (EC) reference values, the mean ESDs were found to be below the reference values in only two of the hospitals. The ranges found in this work are high and this indicates more attention needs to be given to X-ray facilities in the country. This also suggests that radiographic departments need to review their radiographic practices in order to bring their doses to optimum levels. Effective doses were also calculated from the ESD values. The mean effective doses were found to be generally low when compared with those found in the literature from other countries including two African countries. The radiographic parameters used for all the patients were also compared with the European criteria. It is recommended that the tube filtration at one hospital be increased. The importance of good regulatory activities and trained personnel is stressed in this work. Apart from the fact that the data provided in this work will be useful for the formulation of national guidance levels, they also provide patient dosimetry information on healthcare level IV countries.
机译:在尼日利亚,热发光剂量仪(TLD)已用于测量接受骨盆,腹部和腰椎诊断X射线检查的患者的入口表面剂量(ESD)。这项调查总共包括三所公立医院和171名患者。所涉患者的年龄为40岁至85岁,体重从64公斤至73公斤不等。报告了ESD的平均值,中位数,第一和第三四分位数。结果表明,在大多数情况下,对于每项检查,发现其单独的ESD值分别与加纳和坦桑尼亚的可比并更高。还发现平均ESD值在非洲以外国家先前报告的平均ESD值范围内。与欧洲共同体(EC)参考值比较时,仅两家医院的平均ESD被发现低于参考值。在这项工作中发现的范围很高,这表明需要对该国的X射线设施给予更多关注。这也表明放射线部门需要审查其放射线实践,以使其剂量达到最佳水平。还从ESD值计算有效剂量。与其他国家(包括两个非洲国家)的文献中的平均有效剂量相比,发现该平均有效剂量通常较低。还对所有患者使用的射线照相参数与欧洲标准进行了比较。建议增加一所医院的试管过滤。这项工作强调了良好的监管活动和训练有素的人员的重要性。除了这项工作中提供的数据可用于制定国家指导水平的事实外,它们还提供有关IV级医疗保健国家/地区的患者剂量信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号