首页> 外文期刊>International Journal of Fracture >FRACTURE TOUGHNESS TEST WITH A SHARP NOTCH INTRODUCED BY FOCUSSED ION BEAM
【24h】

FRACTURE TOUGHNESS TEST WITH A SHARP NOTCH INTRODUCED BY FOCUSSED ION BEAM

机译:离子束聚焦引起的断裂韧性测试

获取原文
获取原文并翻译 | 示例
           

摘要

The validity of fracture toughness data obtained from tests with V-notched bending bars is affected by the notch root radius and the presence of R-curve behavior. A macroscopic test specimen has been developed that contains a notch introduced by focused ion beam machining. This produces a notch root radius of less than 0.1 mu m, so that notch effects can be ignored for most ceramics. Also, due to the very small notch depths the influence of a rising R-curve should be very close to that of natural cracks. First tests, carried out on a Ce-doped zirconia ceramic resulted in a toughness of K_(Ic) approx = 5.9 MPam ~(1/2).
机译:从V形弯曲钢筋的测试中获得的断裂韧性数据的有效性受切口根部半径和R曲线行为的影响。已经开发出了宏观试样,其包含通过聚焦离子束加工引入的缺口。这样会产生小于0.1微米的缺口根半径,因此对于大多数陶瓷而言,缺口效应可以忽略。同样,由于槽口深度很小,上升的R曲线的影响应该与自然裂缝的影响非常接近。在掺Ce的氧化锆陶瓷上进行的首次测试得出的K_(Ic)韧性约为5.9 MPam〜(1/2)。