The standard relay arrangement can only identify one point (on the process frequency response) from the resultant stationary oscillations. In this paper, a new technique for process frequency response identification is presented, which can identify multiple points on the process frequency response from a single relay feedback test. A new relay, called cascade relay, is proposed and it can effectively excite a process not only at the process critical frequency omega (c) but also at 0:5 omega (c) and 1: 5 omega (c). Guidelines for relay parameters selection are suggested. The process frequency response at multiple frequencies can be accurately estimated from one relay test using the FFT algorithm. The proposed method is robust to noise and step-like load disturbance. The technique can also be easily extended to identify other frequency response points of interest. Simulation shows its effectiveness. [References: 20]
机译:标准继电器装置只能从产生的固定振荡中识别一个点(在过程频率响应上)。在本文中,提出了一种新的过程频率响应识别技术,该技术可以从单个继电器反馈测试中识别过程频率响应的多个点。提出了一种称为级联继电器的新型继电器,它不仅可以在过程临界频率ω(c),而且可以在0:5ω(c)和1:5ω(c)处有效地激发过程。建议选择继电器参数的准则。可以使用FFT算法从一项中继测试中准确估算出多个频率下的过程频率响应。所提出的方法对噪声和阶梯状负载扰动具有鲁棒性。该技术还可以轻松扩展以识别其他感兴趣的频率响应点。仿真表明了其有效性。 [参考:20]