【24h】

In the footsteps of nature.

机译:在自然的脚步声中。

获取原文
获取原文并翻译 | 示例
           

摘要

Occlusal performance is a substantial determinant of the quality of dental prosthetic restorations. In the follow-up (SHIP 1) to the Study of Health in Pomerania (SHIP), a representative population of 3300 subjects was studied in the first exploratory evaluation of the occlusion of artificial teeth in the chewing center (first molar region) of partial dentures. A digital analysis of interocclusal records of habitual intercuspation position (ICP) was performed using the Greifswald Digital Analyzing System (GEDAS), a software package that identifies contact points as transparent areas. 562 subjects (280 men aged 61.7 ± 11.9 years and 282 women aged 60.7 ± 10.7 years) had maxillary removable partial dentures (RPDs), and 619 (271 men aged 65.0 ± 11.5 years and 348 women aged 62.4 ± 10.6 years) had mandibular RPDs. Most RPDs were retained with either attachment retainers (11.7% maxilla, 11.7% mandible), cast clasps (38.4% maxilla, 40.7% mandible), telescopes with double crowns (15.7% maxilla, 19.1% mandible), or wrought wire clasps (16.4% maxilla, 8.2% mandible). Some had a combination of different retention elements. The mean number of artificial teeth was 7.8 ± 2.9 in the maxilla and 7.5 ± 3.0 in the mandible. Only the artificial teeth (first molars) in mandibular partial dentures showed differences in the frequency of occlusal contacts between groups (chi-square test). Of these, telescopic crown-retained RPDs had the highest frequency of occlusal contacts (74.4% at tooth 36 and 77.1% at tooth 46), and wrought wire-retained RPDs had the lowest (48.4% at tooth 36 and 45.2% at tooth 46). The results for RPDs with a free-end saddle were comparable and analogous; contact frequencies for those with an interdental saddle did not differ significantly. Notably, the overall frequency of occlusal contacts was greater for tooth 46 (62.9%) than for tooth 36. In conclusion, when replacing teeth in the chewing center, particularly in the mandible, telescopic crown-retained RPDs offer a distinct advantage in terms of occlusal contacts and thus provide better occlusal stability.
机译:咬合性能是假牙修复体质量的重要决定因素。在对波美拉尼亚健康研究(SHIP)的后续行动(SHIP 1)中,对3300名受试者的代表性人群进行了首次探索性评估,评估了部分牙齿的咀嚼中心(第一磨牙区)人造牙的咬合情况。假牙。使用格赖夫斯瓦尔德数字分析系统(GEDAS)对习惯性发作位置(ICP)的咬合间记录进行了数字分析,该软件包将接触点识别为透明区域。 562名受试者(280名男性,年龄为61.7±11.9岁,282名女性,年龄为60.7±10.7岁),具有上颌可摘局部义齿(RPDs),以及619名(271名男性,年龄为65.0±11.5岁,348名女性,年龄为62.4±10.6岁),具有下颌RPD。 。大多数RPD都配有附件固定器(上颌骨11.7%,下颌骨11.7%),铸扣(上颌骨38.4%,下颌骨40.7%),双冠望远镜(上颌骨15.7%,下颌骨19.1%)或锻造金属丝钩(16.4) %上颌骨,下颌骨8.2%)。有些组合了不同的保留元素。上颌的人造牙平均数为7.8±2.9,下颌骨的平均数为7.5±3.0。下颌部分假牙中只有假牙(第一磨牙)在各组之间的咬合接触频率上存在差异(卡方检验)。在这些中,可伸缩的冠状保留RPD具有最高的咬合接触频率(在牙齿36处为74.4%,在牙齿46处为77.1%),而在金属丝保留的RPD中具有最低的咬合接触频率(在牙齿36处为48.4%,在牙齿46处为45.2%)。 )。具有自由端鞍座的RPD的结果是可比的和相似的。齿间鞍的接触频率没有显着差异。值得注意的是,牙齿46的总咬合频率(62.9%)比牙齿36更大。总而言之,在咀嚼中心(尤其是下颌骨,伸缩式冠状保留RPD)中更换牙齿时,在以下方面具有明显优势:咬合接触,从而提供更好的咬合稳定性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号