BACKGROUND: Good communication between an operating clinician and the attending radiographer when using C-arm fluoroscopy is vital. Efficient and safe use of ionising radiation protects all theatre staff. The object of this study was to design and test a single communication language for use in all fluoroscopy-assisted procedures. METHOD: A clinician guiding a radiographer performed a control 'no-rules' experiment of 56 targeting manoeuvres with a fluoroscopic C-arm on a scientific model. A single beam laser replaced the usual ionising radiation beam. The time taken for each targeting along with the laser exposure required was recorded. Following a period of instruction, the experiment was repeated using only our pre-defined communication strategy. The data was collected for statistical analysis. RESULTS: A statistically significant reduction was seen in the time taken for each targeting manoeuvre and the laser exposure required when using our strategy. CONCLUSION: This study shows that using our pre-prepared communication strategy could significantly improve efficiency and safety of fluoroscopic C-arm use.
机译:背景:在使用C型臂透视检查时,临床医生和射线照相医师之间的良好沟通至关重要。有效安全地使用电离辐射可保护所有剧院工作人员。这项研究的目的是设计和测试一种在所有荧光检查辅助程序中使用的单一交流语言。方法:指导放射线照相的临床医生在科学模型上进行了用荧光镜C型臂进行的56次瞄准演习的对照“无规则”实验。单束激光代替了常规的电离辐射束。记录每个目标所花费的时间以及所需的激光照射。经过一段时间的指导,仅使用我们预先定义的交流策略重复进行该实验。收集数据进行统计分析。结果:使用我们的策略时,每次瞄准动作所需的时间和所需的激光照射在统计上均显着减少。结论:这项研究表明,使用我们预先准备的沟通策略可以显着提高荧光透视C型臂使用的效率和安全性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号