...
首页> 外文期刊>Astrophysics and space science >Characteristics of DH type II bursts, CMEs and flares with respect to the acceleration of CMEs
【24h】

Characteristics of DH type II bursts, CMEs and flares with respect to the acceleration of CMEs

机译:DH II型爆发,CME和耀斑相对于CME加速度的特征

获取原文
获取原文并翻译 | 示例
           

摘要

A detailed investigation on DH-type-II radio bursts recorded in Deca-Hectometer (hereinafter DH-type-II) wavelength range and their associated CMEs observed during the year 1997-2008 is presented. The sample of 212 DH-type-II associated with CMEs are classified into three populations: (i) Group I (43 events): DH-type-II associated CMEs are accelerating in the LASCO field view (a > 15 m s ~(-2)); (ii) Group II (99 events): approximately constant velocity CMEs (-15 < a < 15 m s ~(-2)) and (iii) Group III (70 events): represents decelerating CMEs (a<-15 m s ~(-2)). Our study consists of three steps: (i) statistical properties of DH-type-II bursts of Group I, II and III events; (ii) analysis of time lags between onsets of flares and CMEs associated with DH-type-II bursts and (iii) statistical properties of flares and CMEs of Group I, II and III events. We found statistically significant differences between the properties of DH-type-II bursts of Group I, II and III events. The significance (P _a) is found using the one-way ANOVA-test to examine the differences between means of groups. For example, there is significant difference in the duration (P _a=5%), ending frequency (P _a=4%) and bandwidth (P _a=4%). The accelerating and decelerating CMEs have more kinetic energy than the constant speed CMEs. There is a significant difference between the nose height of CMEs at the end time of DH-type-IIs (P _a?1%). From the time delay analysis, we found: (i) there is no significant difference in the delay (flare start-DH-type-II start and flare peak-DH-type-II start); (ii) small differences in the time delay between the CME onset and DH-type-II start, delay between the flare start and CME onset times. However, there are high significant differences in: flare duration (P _a=1%), flare rise time (P _a=0. 5%), flare decay time (P _a=5%) and CMEs speed (P _a?1%) of Group I, II and III events. The general LASCO CMEs have lower width and speeds when compared to the DH CMEs. It seems there is a strong relation between the kinetic energy of CMEs and DH-type-II properties.
机译:介绍了对在Dec-Hectometer(以下称DH-II型)波长范围内记录的DH-II型无线电脉冲及其相关的CME进行的详细研究,它们在1997-2008年期间被观测到。 212种与CME相关的DH-II型样本被分为三类:(i)第I组(43个事件):在LASCO视野中,与DH-II型相关的CME加速了(a> 15 ms〜(- 2)); (ii)II组(99个事件):近似恒定速度的CME(-15 <15 ms〜(-2))和(iii)III组(70个事件):代表减速的CME(a <-15 ms〜( -2))。我们的研究包括三个步骤:(i)第I,II和III组事件的DH型II爆发的统计特性; (ii)分析与DH型II爆发相关的耀斑和CME发作之间的时滞,以及(iii)第I,II和III组事件的耀斑和CME的统计特性。我们发现组I,II和III的事件的DH型II爆发的属性之间具有统计学上的显着差异。显着性(P _a)使用单向ANOVA检验来检验组均值之间的差异。例如,持续时间(P _a = 5%),结束频率(P _a = 4%)和带宽(P _a = 4%)存在显着差异。加速和减速CME比定速CME具有更多的动能。在DH型IIs结束时,CME的鼻子高度之间存在显着差异(P _a?1%)。从时间延迟分析中,我们发现:(i)延迟之间没有显着差异(耀斑开始-DH-II型起始和耀斑峰-DH-II型起始); (ii)CME发作与DH-II型发作之间的时间延迟,火炬开始与CME发作时间之间的延迟差异很小。但是,在耀斑持续时间(P _a = 1%),耀斑上升时间(P _a = 0。5%),耀斑衰减时间(P _a = 5%)和CMEs速度(P _a?1)方面存在很高的显着差异。 I,II和III组比赛的百分比)。与DH CME相比,一般的LASCO CME具有较低的宽度和速度。 CME的动能与DH-II型特性之间似乎存在很强的关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号