首页> 外文期刊>Archives of orthopaedic and trauma surgery. >Quantitative anatomic basis of antegrade lag screw placement in posterior column of acetabulum.
【24h】

Quantitative anatomic basis of antegrade lag screw placement in posterior column of acetabulum.

机译:髋臼后柱顺行拉力螺钉放置的定量解剖学基础。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Lag screw fixation has been recommended for treatment of acetabular and pelvic fracture for several years. The aim of the present study was to determine the projection of the axis of the posterior column on the inner table of the iliac wing in the supra-acetabular region. METHODS: Thirty adult dried bony hemipelves specimens and other five intact adult dried pelvic specimens were included in this study. The projection point of the axis of the posterior column of the acetabulum was determined on the inner table of the iliac wing of the hemipelves specimens. The perpendicular distance from the optimal entry point to the linea terminalis of pelvis was measured and recorded as the lateral distance. The same measurement along the linea terminalis from the optimal entry point to the junction between the anterior border of iliosacral articulation and the linea terminalis of pelvis was made and recorded as the posterior distance. The depth of the anchor path and the corresponding average retroversion angulation and extraversion angulation were also measured. According to the results acquired from this study, a series of 6.5 mm lag screws were inserted into the posterior column of each side of the other five intact specimens, respectively, to evaluate the position of the screws. The data were expressed as mean +/- SD and analyzed by using the descriptive methods with SPSS 10.0. RESULTS: The average length of lag screw was 104.8 +/- 4.2 mm. The average lateral distance was 16.8 +/- 2.1 mm. The average posterior distance was 23.5 +/- 3.4 mm. The corresponding average retroversion angulation and extraversion angulation were 57 degrees 36' +/- 4 degrees 28' and 119 degrees 18' +/- 2 degrees 32', respectively. The insertion of the single 6.5 mm lag screw of adequate length was possible in the posterior column along its anchor path and no accidental extraosseous or intraarticular screw placement had occurred. CONCLUSIONS: The present study describes a safe anchor path of antegrade lag screw fixation in the posterior column. Insertion of the lag screws of adequate length is possible in the posterior column along its functional axis.
机译:背景:多年以来,推荐使用滞后螺钉固定术治疗髋臼和骨盆骨折。本研究的目的是确定后髋臼轴在髋臼上区region骨内表上的投影。方法:本研究包括30个成年干骨半盆标本和其他5个完整的成年干骨盆标本。髋臼后柱轴的投影点在半骨标本的wing翼内表上确定。测量从最佳进入点到骨盆末端的垂直距离,并将其记录为横向距离。从最佳进入点到骨关节前缘与骨盆的终末界之间的交界处,沿终末界进行相同的测量,并将其记录为后距离。还测量了锚固路径的深度以及相应的平均后倾角和外倾角。根据从这项研究中获得的结果,将一系列6.5 mm滞后螺钉分别插入到其他五个完整样本的每一侧的后柱中,以评估螺钉的位置。数据表示为平均值+/- SD,并使用SPSS 10.0的描述性方法进行分析。结果:方头螺钉的平均长度为104.8 +/- 4.2毫米。平均横向距离为16.8 +/- 2.1毫米。后平均距离为23.5 +/- 3.4毫米。相应的平均后倾角和外倾角分别为57度36'+/- 4度28'和119度18'+/- 2度32'。可以在后柱沿其锚固路径插入一根足够长的6.5 mm滞后螺钉,并且没有发生意外的骨外或关节内螺钉放置的情况。结论:本研究描述了前柱后路螺钉固定在后柱的安全锚固路径。可以在后柱沿其功能轴插入足够长的方头螺钉。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号