INTRODUCTION: Ultrasound examination of infant hips is a widely used and accepted tool for the diagnosis and monitoring of developmental dysplasia of the hip. Its use and timing is still a focus of debate and its diagnostic accuracy has not been fully investigated. METHOD: We have compared the ultrasound findings by the Graf technique with radiographic appearance (acetabular index) at 6 months of age. RESULT: The negative predictive value of Ultrasound for DDH was 98% and was unaffected by the timing of the examination. The specificity and accuracy of the examination increased with age and was highest at 3 months of age. CONCLUSION: Ultrasound examination of the infant hip by the static Graf technique is a safe and effective screening tool for the evaluation of DDH.
机译:引言:婴儿髋部的超声检查是诊断和监测髋部发育不良的一种广泛使用和公认的工具。它的使用和时间仍然是争论的焦点,其诊断准确性还没有得到充分研究。方法:我们将通过Graf技术进行的超声检查结果与6个月大时的影像学表现(髋臼指数)进行了比较。结果:超声对DDH的阴性预测值为98%,不受检查时间的影响。检查的特异性和准确性随年龄增长而增加,在3个月大时最高。结论:静态Graf技术对婴儿髋部进行超声检查是评估DDH安全有效的筛查工具。