首页> 外文期刊>Applied thermal engineering: Design, processes, equipment, economics >An experimental study on the operating performance of a novel reverse-cycle hot gas defrosting method for air source heat pumps
【24h】

An experimental study on the operating performance of a novel reverse-cycle hot gas defrosting method for air source heat pumps

机译:空气源热泵新型逆循环热气除霜方法运行性能的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

This paper reports on an experimental study on the operating performance for a novel reverse-cycle hot gas defrosting method for air source heat pumps (ASHPs). Firstly, a description of both an experimental prototype ASHP unit where the novel reverse-cycle hot gas defrosting method may be realized, and its operating modes are presented. This is followed by reporting an experimental set up for testing the defrosting performance of the prototype ASHP unit using the novel thermal energy storage (TES) based reverse-cycle hot gas defrosting method. Finally, experimental results are presented and discussed. The experimental results suggested that the use of the novel reverse-cycle hot gas defrosting method for the experimental ASHP unit was able to help shorten the defrosting time by ~3 min or 38%, and minimize the risk of shutting down the ASHP unit due to low suction pressure through increasing the compressor's suction pressure by about 200 kPa, when compared to the use of the traditional standard reverse-cycle hot gas defrosting method. In addition, when the TES based reverse-cycle hot gas defrosting method was used, the mean indoor coil surface temperature during defrosting was about 25 K higher than that when the traditional standard reverse-cycle hot gas defrosting method was used. These results suggested that as compared to the use of the traditional standard reverse-cycle hot gas defrosting method, the use of the novel TES based defrosting method would enable a quicker space heating resumption, impacting less on indoor thermal environment due to defrosting. Hence, the novel TES based defrosting method was proven to be effective in reducing the current problems in ASHPs using standard reverse-cycle hot gas defrosting method, such as a longer defrosting time and a poor system reliability.
机译:本文报告了一种用于空气源热泵(ASHP)的新型反向循环热气除霜方法的运行性能的实验研究。首先,描述了可以实现新型逆循环热气除霜方法的实验原型ASHP装置,并介绍了其工作模式。接下来是报告一个实验装置,该实验装置使用基于新型热能存储(TES)的反向循环热气除霜方法测试ASHP原型机的除霜性能。最后,提出并讨论了实验结果。实验结果表明,将新型逆循环热气除霜方法用于ASHP实验装置,可将除霜时间缩短约3分钟或38%,并最大程度地减少了由于以下原因而关闭ASHP装置的风险:与使用传统的标准反向循环热气除霜方法相比,可通过将压缩机的吸入压力提高约200 kPa来降低吸入压力。另外,当使用基于TES的反向循环热气除霜方法时,除霜期间室内盘管的平均表面温度比使用传统的标准反向循环热气除霜方法高约25K。这些结果表明,与使用传统的标准反向循环热气除霜方法相比,使用基于TES的新型除霜方法可以更快地恢复空间供热,除霜对室内热环境的影响较小。因此,事实证明,基于TES的新型除霜方法可有效减少使用标准反向循环热气除霜方法在ASHP中的当前问题,例如更长的除霜时间和较差的系统可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号