Objective assessment of patient compliance with removable orthodontic appliances: A cross-sectional cohort study

机译:客观评估患者对可移动正畸矫治器的依从性:一项横断面队列研究

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors. Materials and Methods: Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex. Results: There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55-318 days) the actual wear time was 9.0 h/d (range, 0.0-16.0 h/d) and did not differ between distinct prescriptions (P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5%(range, 0.0-89.3%) for the 14 h/d and 112.5% (range, 0.0-200.0%) for the 8 h/d prescription wear (P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = -0.61, P = .00; 8 h/d prescription: n = 24, rho = -0.73, P = .00), while sex did not exert a significant influence on compliance (P = .58). Conclusions: Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.
机译:目的:客观评估患者对可移动正畸矫治器的依从性以及可能影响因素的影响。材料和方法:借助TheraMon微传感器记录了45名白人患者的佩戴时间。相对于佩戴处方和其他参数(例如年龄和性别)评估了患者的依从性。结果:在大多数测量变量以及所有组/亚组中,个体差异较高。在186天(范围为55-318天)的中位观察期内,实际佩戴时间为9.0 h / d(范围为0.0-16.0 h / d),不同处方之间无差异(P = 0.49)。八名患者的电器不足2小时/天,其中六名根本没有佩戴电器。总体而言,相对于处方而言,每天14小时的平均磨损为62.5%(范围0.0-89.3%),而每天8小时的处方磨损为112.5%(范围0.0-200.0%)(P =)。 01)组。年龄(中位数:12.5岁)与每天实际佩戴时间相对于佩戴处方(14 h / d处方:n = 21,rho = -0.61,P = .00; 8)的强烈负相关性h / d处方:n = 24,rho = -0.73,P = 0.00),而性别对依从性没有显着影响(P = .58)。结论:尽管患者和父母都知道了佩戴时间记录,但功能治疗(14 h / d处方)的依从性不足,而保留治疗(8 h / d处方)的依从性却足够。由于患者的依从性是一个高度可变的问题,因此需要客观的措施来评估对可移动正畸器具的依从性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号