...
首页> 外文期刊>Analytical and bioanalytical chemistry >Sediment certified reference materials for the determination of polychlorinated biphenyls and organochlorine pesticides from the National Metrology Institute of Japan (NMIJ)
【24h】

Sediment certified reference materials for the determination of polychlorinated biphenyls and organochlorine pesticides from the National Metrology Institute of Japan (NMIJ)

机译:日本国家计量学会(NMIJ)的沉积物认证参考物质,用于测定多氯联苯和有机氯农药

获取原文
获取原文并翻译 | 示例
           

摘要

Two marine sediment certified reference materials, NMIJ CRM 7304-a and 7305-a, have been issued by the National Metrology Institute of Japan in the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) for the determination of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs). The raw materials of the CRMs were collected from a bay near industrial activity in Japan. Characterization of these CRMs was conducted by NMIJ, where the sediments were analyzed using multiple analytical methods such as pressurized liquid extraction (PLE), microwave-assisted extraction (MAE), saponification, Soxhlet extraction, supercritical fluid extraction (SFE), and ultrasonic extraction; the target compounds were determined by one of the primary methods of measurements, isotope dilution-mass spectrometry (ID-MS). Certified values have been provided for 14 PCB congeners (PCB numbers 3, 15, 28, 31, 70, 101, 105, 138, 153, 170, 180, 194, 206, 209) and 4 OCPs (gamma-HCH, 4,4'-DDT, 4,4'-DDE, 4,4'-DDD) in both CRMs. NMIJ CRM 7304-a has concentrations of the contaminants that are a factor of 2-15 greater than in CRM 7305-a. Both CRMs have information values for PCB homolog concentrations determined by collaborative analysis using a Japanese official method for determination of PCBs. The total PCB concentrations in the CRMs are approximately 920 and 86 mu g kg(-1) dry mass respectively.
机译:日本国家计量学会在国家先进工业科学技术研究院(NMIJ / AIST)发行了两种经海洋沉积物认证的参考材料NMIJ CRM 7304-a和7305-a,用于测定多氯联苯(PCBs) )和有机氯农药(OCP)。 CRM的原材料是从日本工业活动附近的一个海湾收集的。这些CRM的表征是由NMIJ进行的,其中使用多种分析方法对沉积物进行分析,例如加压液体萃取(PLE),微波辅助萃取(MAE),皂化,索氏萃取,超临界流体萃取(SFE)和超声萃取;通过主要的测量方法之一同位素稀释质谱法(ID-MS)确定目标化合物。已为14个PCB同类产品(PCB编号3、15、28、31、70、101、105、138、153、170、180、194、206、209)和4个OCP(γ-HCH,4,两个CRM中的4'-DDT,4,4'-DDE,4,4'-DDD)。 NMIJ CRM 7304-a的污染物浓度比CRM 7305-a高2-15倍。两种CRM均具有PCB同源物浓度的信息值,该信息是通过使用日本官方方法确定PCB进行协作分析确定的。 CRM中的总PCB浓度分别约为920和86μg kg(-1)干质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号