首页> 外文期刊>Applied radiation and isotopes: including data, instrumentation and methods for use in agriculture, industry and medicine >Performance evaluation of a Compton SPECT imager for determining the position and distribution of (225)AC in targeted alpha therapy: A Monte Carlo simulation based phantom study
【24h】

Performance evaluation of a Compton SPECT imager for determining the position and distribution of (225)AC in targeted alpha therapy: A Monte Carlo simulation based phantom study

机译:康普顿SPECT成像仪的性能评估确定靶向α治疗中(225)AC的位置和分布:基于蒙特卡罗模拟的幻影研究

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, the performance of a Compton Single Photon Emission Computed Tomography (SPECT) imager when in vivo monitoring the position and distribution of (225)AC radionuclide in targeted alpha therapy (TAT) was evaluated. When (225)AC radionuclide, which emits various gamma-rays (218 and 440 keV), is used in TAT, both the photoelectric and Compton scattering events can be used for image reconstruction. Moreover, all information pertaining to the various gamma-rays of the (225)AC radionuclide can be individually or simultaneously utilized in the reconstructed image. Three types of simulation phantoms and a quantitative evaluation method were used to compare the performance of the Compton SPECT imager to that of conventional SPECT imaging, which uses only photoelectric events, and the results demonstrated that the Compton SPECT imager exhibited a higher performance as the effective count for the image reconstruction was higher. To verify the accuracy of the position and distribution of the Ac-225 radionuclide that had been inserted into the phantom, reconstructed images of the various gamma-rays were combined with cross-sectional images of the human phantom and all combined images were found to match the predetermined simulation conditions. In conclusion, the simulation results demonstrated the feasibility of the in vivo monitoring of the position and distribution of Ac-225 radionuclide using the gamma-rays in TAT.
机译:在该研究中,评估康普顿单光子发射计算断层摄影(SPECT)成像器的性能,监测靶向α治疗(TAT)中(225)AC放射性核素的位置和分布(TAT)。当(225)发出各种伽马射线(218和440keV)的AC放射核素在TAT中使用时,光电和康普顿散射事件都可以用于图像重建。此外,与(225)AC放射性核素的各种γ射线有关的所有信息可以单独地或同时在重建的图像中使用。使用三种类型的仿真幽灵和定量评估方法将Compton Spect成像仪与仅使用光电事件的常规SPECT成像的性能进行比较,结果表明康普顿SPECT成像仪表现出更高的性能作为有效的性能计算图像重建的计数更高。为了验证已插入模体中的AC-225放射性核素的位置和分布的准确性,将各种γ射线的重建图像与人类幻像的横截面图像结合,并且发现所有组合图像匹配预定的模拟条件。总之,仿真结果表明,使用TAT中的γ射线对AC-225放射性核素的位置和分布的体内监测的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号