...
首页> 外文期刊>Analytical and bioanalytical chemistry >Critical evaluation of the use of total reflection X-ray fluorescence spectrometry for the analysis of whole blood samples: application to patients with thyroid gland diseases
【24h】

Critical evaluation of the use of total reflection X-ray fluorescence spectrometry for the analysis of whole blood samples: application to patients with thyroid gland diseases

机译:全反射X射线荧光光谱法用于分析全血样品的关键评价:对甲状腺疾病患者的应用

获取原文
获取原文并翻译 | 示例
           

摘要

Multielemental analysis of whole blood can provide significant information for the evaluation of nutritional status and diagnosis of certain diseases as well as for the assessment of exposure to potentially toxic metals. However, the quantification of multiple elements in whole blood is not easy partly because of the wide variation in element concentrations (from ngL(-1) to gL(-1)) and the complex matrix. The aim of this work was to develop a fast, sustainable, and reliable analytical method, in combination with low-power TXRF, for multielemental analysis of blood samples. Firstly, a set of experiments were carried out to select the best diluent type and dilution factor using the control material SeronormTM Trace Elements Whole Blood L-1. A critical evaluation of the parameters affecting the sample deposition on the reflector was also carried out including a study of the shape and element distribution of the deposited residue on the reflector by micro X-ray fluorescence spectrometry. Using the best analytical conditions, limits of detection estimated were in the low milligrams per kilogram range and similar to those obtained using more complex sample treatments such as digestion. Accuracy and precision of the results were in most cases acceptable (recoveries 89-102%, RSD 6-8%, n=5). Only underestimated values were obtained for light elements such as potassium. To prove the applicability of the method, several blood samples from control and thyroid disease patients were analyzed. Despite the fact that more samples need to be analyzed, it seems that Zn and Br contents in some of the patients are significantly higher compared to control samples.
机译:全血的多元素分析可以提供评估营养状况和某些疾病诊断的重要信息,以及对潜在有毒金属的暴露评估。然而,由于元件浓度的宽变化(从NgL(-1)至gl(-1))和复杂基质,全血中多血中多种元素的定量并不容易。这项工作的目的是开发一种快速,可持续和可靠的分析方法,与低功率TXRF组合,用于血样的多元素分析。首先,进行一组实验以选择使用对照材料SeronormTM微量元素全血L-1选择最佳的稀释剂类型和稀释因子。还对影响反射器上的样品沉积的参数的关键评估还进行了通过微X射线荧光光谱法对反射器上沉积的残余物的形状和元素分布的研究。使用最佳的分析条件,估计的检测限估计在每千克范围的低毫克,并且类似于使用更复杂的样品处理,例如消化的那些。结果的准确性和精度在大多数情况下可接受(回收89-102%,RSD 6-8%,n = 5)。仅获得低估值,用于诸如钾的轻质元素。为了证明该方法的适用性,分析了来自对照和甲状腺疾病患者的几种血液样本。尽管需要分析更多样本,但与对照样品相比,一些患者的Zn和Br内容显着更高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号