首页> 外文期刊>American Journal of Infection Control >Effectiveness of stringent decontamination of computer input devices in the era of electronic medical records and bedside computing: A randomized controlled trial
【24h】

Effectiveness of stringent decontamination of computer input devices in the era of electronic medical records and bedside computing: A randomized controlled trial

机译:电子病历和床边计算机时代对计算机输入设备进行严格消毒的有效性:一项随机对照试验

获取原文
获取原文并翻译 | 示例
           

摘要

Bedside computing may lead to increased hospital-acquired infections mediated by computer input devices handled immediately after patient contact. We compared 2 decontamination methods in 2 types of wards. We found high baseline contamination rates, which decreased following decontamination, but the rates remained unacceptably high. Decontamination was more effective in intensive care units compared with medical wards and when using alcohol-based impregnated wipes compared with quaternary ammonium-based impregnated wipes. Copyright (C) 2015 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
机译:床旁计算可能会导致由患者接触后立即处理的计算机输入设备介导的医院获得性感染的增加。我们比较了两种病房中的两种去污方法。我们发现基线污染率很高,去污后污染率降低了,但污染率仍然高得令人无法接受。与医疗病房相比,重症监护病房的去污效果更好,与季铵盐基浸渍的湿巾相比,使用酒精基浸渍纸巾的去污效果更好。感染控制和流行病学专业人员协会版权所有(C)2015。ElsevierInc.保留所有权利。