首页> 外文期刊>American Journal of Orthodontics and Dentofacial Orthopedics >Efficacy of the Nance appliance as an anchorage-reinforcement method
【24h】

Efficacy of the Nance appliance as an anchorage-reinforcement method

机译:Nance设备作为锚固加固方法的功效

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction: The Nance appliance is widely considered to be an efficient method of anchorage reinforcement; however, much of the perceived advantage is based on clinical judgment. The aim of this study was to assess the amounts of anchorage loss and desired tooth movement associated with the Nance appliance. Methods: The mandibular arches of 7 beagle dogs were used. The first and third premolars were extracted. Reference mini-screws were placed at the first premolar sites as stable references to measure the amounts of anchorage loss and desired tooth movement. Four beagles were fitted with custom-made Nance appliances on the fourth premolars and orthodontic bands on the second premolars (Nance group). Three beagles were fitted with orthodontic bands on the second and fourth premolars with no anchorage reinforcement (control group). The second premolars were retracted over 15 weeks in both groups. The amounts of second premolar movement (desired tooth movement) and fourth premolar movement (anchorage loss) were recorded at 5, 10, and 15 weeks. The percentages of desired tooth movement and anchorage loss to the total space closure were calculated. Results: The mean desired tooth movement was significantly more in the Nance group than in the control group at 10 weeks (P<0.05) but was not significantly different at 5 and 15 weeks. The mean percentages of anchorage loss to the total space closure at 15 weeks were 45.7% in the control group and 28.8% in the Nance group. The Nance group had 16.9% less anchorage loss and 16.6% more desired tooth movement than did the control group at 15 weeks (P<0.05). Most of the anchorage loss (80%) in the Nance group occurred during the first 10 weeks. Conclusions: The Nance appliance did not provide absolute anchorage, but there was significantly less anchorage loss with it than in the control group. The majority of anchorage loss occurred during the first 10 weeks in the Nance group.
机译:简介:Nance设备被广泛认为是一种有效的锚固加固方法。但是,许多可察觉的优势是基于临床判断。这项研究的目的是评估与Nance矫治器相关的锚固损失和所需的牙齿运动量。方法:使用7只比格犬的下颌弓。提取第一和第三前磨牙。将参考微型螺钉放置在第一前磨牙部位,作为稳定的参考,以测量固定损失和所需牙齿移动的量。四只小猎犬在第四个前磨牙上装有定制的Nance矫正器,在第二个前磨牙上装有正畸矫正带(Nance组)。三只小猎犬在第二和第四颗前磨牙上安装了正畸带,没有固定锚固件(对照组)。两组均在15周内收回第二个前磨牙。在第5、10和15周记录第二次磨牙前运动(所需牙齿运动)和第四次磨牙前运动(锚固丧失)的量。计算出所需的牙齿移动和锚固损失占总空间闭合的百分比。结果:Nance组在10周时的平均期望牙齿运动明显高于对照组(P <0.05),但在5周和15周时没有明显差异。对照组在15周时锚固损失相对于总空间闭合的平均百分比为45.7%,对照组为28.8%。与对照组相比,Nance组在15周时的锚固损失减少了16.9%,所需的牙齿运动增加了16.6%(P <0.05)。 Nance组的大部分锚固损失(80%)发生在最初的10周内。结论:Nance矫治器不能提供绝对的锚固性,但是与对照组相比,其锚固性损失明显更少。在Nance组中,大部分锚固损失发生在最初的10周内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号