Development of Packaged Air Conditioner with Two Phase Pipeline System for Reduced Refrigerant

机译:与 两相 管道系统 空调箱 的研制 ,可降低 制冷剂

获取原文
获取原文并翻译 | 示例
           

摘要

Reduced production of HCFCs is due to start from 1996 aiming at phasing them out by 2020. We have developed a system for use in packaged air conditioners in which refrigerant flows in two phases (the liquid & gas phases) in a interconnecting pipe. As a result, the amount of refrigerant in the system is reduced by 42 approx 77 percent when compared with a conventional system in which refrigerant flows in the liquid phase instead of two phases. Furthermore, it shows a lower drop in performance in the case of a high-head installation.
机译:减少氟氯烃的生产是由于从1996年开始,旨在将它们逐步淘汰2020年。我们开发了一种用于包装的空调系统,其中制冷剂在互连管中的两个相(液体和气相)流动。 结果,与传统系统相比,系统中制冷剂的量减少了42%,在液相中的制冷剂在液相中而不是两相的情况下进行比较。 此外,在高头装置的情况下,它显示出在性能下降的较低下降。