Repeatability and reproducibility of biometry and keratometry measurements using a noncontact optical low-coherence reflectometer and keratometer

机译:使用非接触式光学低相干反射计和角膜曲率计的生物测定法和角膜测定法的可重复性和可重复性

获取原文
获取原文并翻译 | 示例
           

摘要

To evaluate the repeatability, reproducibility, or both of the biometry and keratometry measurements obtained by a new optical low-coherence reflectometer and keratometer (Lenstar LS 900, version 1.10; Haag-Streit). Prospective, comparative, observational study. setting: Private practice, Lynwood, California, and Santa Monica, California. study population: The measurements of the second eye to be operated on of 37 patients between October 2010 and January 2011 were analyzed. observation procedure: The axial length, central corneal thickness, aqueous depth, anterior chamber depth, crystalline lens thickness, white-to-white corneal diameter, as well as the keratometric readings at the flattest meridian, the steepest meridian, the average K, the amount of astigmatism, and the minus astigmatic cylinder axis were measured before surgery on the patient's first eye and were repeated 1 month later before the second eye surgery. main outcome measures: The repeatability and reproducibility of the biometry and keratometry measurements. Intrasession repeatability and intersession reproducibility were excellent with a very low coefficient of variation and high interclass correlation coefficients for all measured parameters. Bland-Altman plots show good correlation for axial length measurements (95% limits of agreement ranging from -0.056 to +0.04 mm), anterior chamber depth (-0.22 to +0.18 mm), crystalline lens thickness (-0.21 to +0.27 mm), corneal diameter (-0.28 to +0.24 mm), average keratometric readings (-0.56 to +0.47 diopters), and amount of astigmatism (-0.58 to +0.40 diopters). The precision of the measurements obtained by the new optical reflectometer and keratometer is extremely high.
机译:要评估通过新的光学低相干反射计和角膜曲率计(Lenstar LS 900,版本1.10; Haag-Streit)获得的生物测定法和角膜测定法的可重复性,可重复性,或同时进行。前瞻性,比较性,观察性研究。地点:加利福尼亚州林伍德市和加利福尼亚州圣莫尼卡市的私人诊所。研究人群:分析了2010年10月至2011年1月之间37例患者的第二只眼的手术测量。观察程序:轴向长度,中央角膜厚度,房水深度,前房深度,晶状体厚度,白色至白色角膜直径,以及最平坦子午线,最陡子午线,平均K,术前在患者的第一只眼上测量了散光量和负像散圆柱轴,并在第二次眼科手术前一个月重复了一次。主要结果指标:生物测定法和角膜测定法的可重复性和可重复性。会话间的可重复性和会话间的可重复性非常出色,所有测量参数的变异系数非常低,组间相关系数很高。 Bland-Altman图显示了轴向长度测量(95%的一致性极限,范围从-0.056至+0.04 mm),前房深度(-0.22至+0.18 mm),晶状体厚度(-0.21至+0.27 mm)具有良好的相关性,角膜直径(-0.28至+0.24毫米),平均角膜曲率读数(-0.56至+0.47屈光度)和散光量(-0.58至+0.40屈光度)。新的光学反射计和角膜曲率计获得的测量精度非常高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号