AIM: The working group on positron emission tomography (PET) of the DGN (German Society of Nuclear Medicine) initiated this first survey to collect and analyse information on the practise of PET in Germany in the year 2008. METHODS: A questionnaire was sent to PET performing facilities (medical practices, hospitals, university hospitals and others) for retrospective data acquisition. Details regarding the equipment and examination procedures were examined as well as indications and number of studies. In addition, the role of PET within the diagnostic process was evaluated. RESULTS: Responses from 65 sites were analysed. Their technical equipment consisted of 77 PET scanners (40 of them were combined PET/CT devices). About 63500 PET studies had been performed with 86% in the field of oncology, 8% in neurology and 3% in cardiology. The radiotracers were labelled with 18F in 91% of the studies, whereas 68Ga was used in 4% and 11C in 3%. The analyses revealed lung tumours as the most investigated tumour entity, followed by malignant lymphoma, tumours of the gastro-intestinal tract and prostate cancer (about 14000, 6000, 5000 and 2000). Corresponding to the new scanners and software procedures, the number of studies with attenuation correction by CT was high (68%) and nearly all studies were reconstructed iteratively (99%). The PET images were analysed quantitatively in the majority of cases (91%). The clinical reports, which included image documentation for the greater part, were posted regularly within 3 days. However, in 70% of the sites electronic transfer possibilities were used additionally to speed up the diagnostic process. The high standard of quality was demonstrated by the fact, that 40 facilities were engaged in a tumour board. Further on, one third of the physicians had gained a PET certification awarded by the DGN. CONCLUSION: Relative to the high general standard of diagnostic instrumentation in Germany, PET is less established, in particular when compared with other industrialised countries such as USA and Switzerland.
机译:目的:DGN正电子排放断层扫描(PET)的工作组(德国核医学学会)启动了第一次调查,收集和分析了2008年德国宠物实践的信息。方法:送达问卷宠物表演设施(医疗实践,医院,大学医院等)回顾性数据采集。审查了有关设备和考试程序的详细信息以及迹象表明和研究数量。此外,评估了PET在诊断过程中的作用。结果:分析了65个地点的回复。他们的技术设备由77个PET扫描仪(其中40个是PET / CT器件组合)。大约63500宠物研究已经在肿瘤学领域进行了86%,神经病学8%和3%的心脏病。在91%的研究中标记了18°F的放射性反射酯,而68Ga以4%和11℃用于3%。该分析显示肺肿瘤作为最多调查的肿瘤实体,其次是恶性淋巴瘤,胃肠道肿瘤和前列腺癌(约14000,6000,5000和2000)。对应于新的扫描仪和软件程序,CT衰减校正的研究数量高(68%),几乎所有研究都迭代地重建(99%)。定量分析PET图像在大多数情况下(91%)。包括更大部件的图像文件的临床报告,在3天内定期发布。然而,在70%的网站中,电子传递可能性另外用于加速诊断过程。事实上证明了高质量的质量,40个设施从事肿瘤委员会。此外,三分之一的医生获得了DGN授予的宠物认证。结论:相对于德国诊断仪器的高通用标准,宠物不太确定,特别是与美国和瑞士等其他工业化国家相比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号