Comparison of Ga-68- and fluorescence-labeled microspheres for measurement of relative pulmonary perfusion in anesthetized pigs

机译:GA-68-和荧光标记的微球的比较测量麻醉猪中相对肺灌注

获取原文
获取原文并翻译 | 示例
           

摘要

Aim: We compared (68)Gallium (Ga-68)- and fluo rescence-labeled microspheres for measurement of pulmonary perfusion distribution in anesthetized pigs without lung injury. Methods: In two mechanically ventilated pigs, the distribution of pulmonary perfusion was marked in vivo with Ga-68- and fluorescence- labeled microspheres in supine and prone position. After each injection, the distribution of Ga-68-labeled microspheres was measured in vivo with positron emission tomography/computed tomography (PET/ CT) in the position in which microspheres were injected and vice versa. The distribution of fluorescence-labeled microspheres was measured ex vivo. Perfusion distributions were compared between methods and postures within four lung regions and along the ventro-dorsal gradient. After each injection of Ga-68-labeled microspheres, changes in ventro-dorsal perfusion gradients induced by repositioning were compared for volume-and mass-normalized PET/CT measurements. Results: Regional and gradient analyses of in vivo and ex vivo measurements, respectively, consistently revealed higher pulmonary perfusion in dorsal than ventral regions in supine positioned animals. Both methods showed more pronounced perfusion gradients in supine compared to prone position. Changes in animal position were associated with alterations in the ventro-dorsal perfusion gradient when volume-, but not mass-normalization was conducted for PET/CT data. Conclusions: Ex vivo fluorescence-and in vivo Ga-68-labeled microspheres measurements revealed similar perfusion distributions. Mass-normalized perfusion measurements by Ga-68-labeled microspheres and PET/CT were not affected by positioning artifacts.
机译:目的:我们比较(68)镓(Ga-68) - 和氟繁殖标记的微球,用于测量麻醉猪的肺灌注分布,没有肺损伤。方法:在两个机械通风猪中,肺灌注的分布在体内用静脉和俯卧位的GA-68和荧光标记的微球标记。在每次注射之后,用正电子发射断层扫描/计算断层扫描/计算断层扫描(PET / CT)测量GA-68标记的微球的分布,其中将微球注入并反之亦然。测量荧光标记的微球的分布。将灌注分布与四肺区内的方法和姿势进行比较,沿着腹部梯度进行比较。在每次注射Ga-68标记的微球后,比较通过重新定位诱导的胃背灌注梯度的变化,用于体积和质量归一化PET / CT测量。结果:体内和离体测量的区域和梯度分析分别始终如一地揭示了仰腹部位于仰卧定位的动物的背部肺灌注。与易于位置相比,两种方法在仰卧时显示出更明显的灌注梯度。当对PET / CT数据进行体积而不是质量标准化时,动物位置的变化与腹腹灌注梯度的改变有关。结论:离体荧光 - 和体内GA-68标记的微球测量显示出类似的灌注分布。通过定位伪影,Ga-68标记的微球和PET / CT的质量归一化灌注测量不受定位伪影的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号