首页> 外文期刊>Journal of medical imaging and radiation sciences >Mammography Dose Survey Using International Quality Standards
【24h】

Mammography Dose Survey Using International Quality Standards

机译:使用国际质量标准进行乳房X线摄影剂量调查

获取原文
获取原文并翻译 | 示例
           

摘要

Digital mammography is the current standard for breast cancer screening. The absence of any dosimetric data, the quality standards, and the fear of radiation detriment, sometimes, hampers the smooth introduction of this technology and the launch of breast cancer screening programmes. As the breast cancer screening programmes are in development in Morocco, quality standards have been set in this study, so that any new breast cancer screening service could get started with their first analysis. The purpose of this study was to report the first Moroccan breast dose and to test quality standards compared with European guidelines. A dosimetric study is conducted by calculating mean glandular dose (MGD) for patients' breasts and polymethyl methacrylate (PMMA) for each thickness from recorded radiographic factors and X-ray tube (output and half-value layer) measurements using Dance's model for a digital mammography system. This is carried out to determine the correlation between phantom and patient measurements. The mean MGD for patient data was 1.02 ± 0.5 mGy and the compressed breast thickness was 55 ± 14 mm. For compressed breast thickness range of 50-60 mm, the MGD was 0.94 ± 0.3 mGy and the dose calculated with PMMA phantom for the same range thickness was 1.33 mGy. The results of MGD as a function of PMMA thickness is lower than the achievable limit curve proposed in the European guidelines. The average doses, which depend on the technical parameters of the mammography equipment, are in line with values obtained in European guidelines. In addition, an investigation is needed throughout the Moroccan territory, in the sense of optimization of radiological practices and techniques in mammographic centres aligning with the international recommendations.
机译:数字乳房X线摄影是乳腺癌筛选的现行标准。缺乏任何单模数据,质量标准,以及对辐射损害的恐惧,有时,妨碍了这种技术的顺利介绍和发射乳腺癌筛查计划。随着乳腺癌筛查计划在摩洛哥发展,本研究已经设定了质量标准,因此任何新的乳腺癌筛查服务都可以开始他们的第一次分析。本研究的目的是报告第一个摩洛哥乳房剂量和与欧洲准则相比的质量标准。通过使用舞蹈模型用于数字的舞蹈模型,通过计算患者乳腺和聚甲基丙烯酸甲酯(PMMA)的平均腺剂量(MGD)来进行剂量测定研究。乳房X线摄影系统。这是为了确定体模和患者测量之间的相关性。患者数据的平均MGD为1.02±0.5米,压缩乳房厚度为55±14毫米。对于压缩的乳房厚度范围为50-60mm,MGD为0.94±0.3米,并且用PMMA幻像计算的剂量为相同的范围厚度为1.33 mg。 MGD作为PMMA厚度的函数的结果低于欧洲准则中所提出的可实现的极限曲线。依赖于乳房X线摄影设备的技术参数的平均剂量符合欧洲指南中获得的值。此外,在摩洛哥领土中需要调查,以优化与国际建议对齐的乳房监视中心的放射实践和技术的优化感。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号