首页> 外文期刊>American journal of dentistry >The effect of toothbrushing on surface gloss of resin composites
【24h】

The effect of toothbrushing on surface gloss of resin composites

机译:牙刷对树脂复合材料表面光泽的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: To determine the changes in surface gloss of different composite materials after laboratory toothbrushing simulation. Methods: 36 specimens were fabricated for each material and polished with 120-, 220-, 500-, 1200-, 2400- and 4000-grit SiC abrasive paper, respectively. Gloss measurements were made with a glossmeter (Novocurve) prior to testing procedures and then subjected to simulated toothbrushing for 5, 15, 30 and 60 minutes by means of an electric toothbrush with a pressure of 2N while being immersed in a 50 RDA toothpaste slurry. Four supplementary samples per group were analyzed under SEM immediately after polishing procedures and four samples after 60 minutes simulated toothbrushing in order to evaluate the causes of the gloss decrease. The tested resin composite materials were Filtek Supreme XTE, Durafill, HRi Enamel Plus, Miris 2, Empress Direct, Venus Diamond, Gradia Direct, Clearfil Photo Posterior and G-aenial. Natural enamel represented the control group. Statistical analysis was performed using Kruskal Wallis and Tukey post-hoc test, with a level of significance set at 0.05. Results: Resin composite initial gloss values ranged from 68.9 to 100.5 at baseline to 10.6 to 62.6 after 1 hour of brushing. Highest gloss values were obtained by Filtek Supreme XTE, followed by Empress Direct and Durafill. Lowest values were obtained by Clearfil Photoposterior, Miris 2, Enamel HRi and Venus Diamond. Natural enamel was the only substrate to maintain its gloss throughout the brushing procedure (110.4 after 60 minutes). SEM analysis revealed different patterns of surface degradation depending on the composite material.
机译:目的:确定模拟牙刷后不同复合材料表面光泽的变化。方法:每种材料分别制作36个样品,并分别用120、220、500、1200、2400和4000粒度的SiC砂纸抛光。在测试程序之前,用光泽度仪(Novocurve)进行光泽度测量,然后将其浸入50 RDA牙膏浆液中,用压力为2N的电动牙刷进行5、15、30和60分钟的模拟牙刷清洁。抛光程序后立即在SEM下对每组四个补充样品进行分析,在模拟牙刷刷牙60分钟后对四个样品进行分析,以评估光泽下降的原因。测试的树脂复合材料为Filtek Supreme XTE,Durafill,HRi Enamel Plus,Miris 2,Empress Direct,Venus Diamond,Gradia Direct,Clearfil Photo后和G-enial。天然搪瓷代表对照组。使用Kruskal Wallis和Tukey事后检验进行统计分析,显着性水平设置为0.05。结果:树脂复合材料的初始光泽度值从基线的68.9至100.5到刷牙1小时后的10.6至62.6。 Filtek Supreme XTE,随后是Empress Direct和Durafill,获得了最高的光泽度值。最低值通过Clearfil Photoposterior,Miris 2,Enamel HRi和Venus Diamond获得。天然搪瓷是在整个刷牙过程(60分钟后为110.4)保持光泽的唯一底材。 SEM分析显示出取决于复合材料的表面降解的不同模式。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号