Dual-Energy Computed Tomography Imaging of Head: Virtual High-Energy Monochromatic (190 keV) Images Are More Reliable Than Standard 120 kV Images for Detecting Traumatic Intracranial Hemorrhages

机译:双能量计算机断层扫描成像头:虚拟高能单色(190keV)图像比标准120 kV图像更可靠,用于检测创伤性颅内出血

获取原文
获取原文并翻译 | 示例
           

摘要

High-energy monochromatic (190 keV) images may be more reliable than standard 120 kV Images for detecting intracranial hemorrhages. We aimed to retrospectively compare virtual high monochromatic (190 keV) and standard 120 kV images from dual-energy computed tomography (CT; DECT) for the diagnosis of intracranial hemorrhages in traumatic brain injury (TBI). We analyzed admission CT studies in 100 trauma patients. Three radiologists independently reviewed four image sets: 120 kV and 190 keV (thin [1 mm] and thick [5 mm] section) images for the presence of various types of intracranial hemorrhages. The proportions of positive variables were compared and differences calculated by McNemar test and sensitivities determined by contingency tables. Randomly selected hemorrhagic lesions were analyzed for contrast index (CI). Thin-section 190 keV images were superior in the detection of subdural hematomas (SDH) (p 0.53) and a large increase in CI of extra-axial hematomas (Cohen's d > 0.86). Our results indicate that virtual high monochromatic (190 keV, thin-section) images combined with standard 120 kV images may provide optimal diagnostic performance for evaluation of patients suspected of TBI.
机译:高能单色(190keV)图像可能比标准120kV图像更可靠,用于检测颅内出血。我们的目的是回顾性地比较虚拟高单色(190keV)和标准的120kV图像,用于诊断创伤性脑损伤(TBI)中的颅内出血的诊断。我们分析了100名创伤患者的入学CT研究。三位放射科医生独立审查了四个图像集:120 kV和190keV(薄[1 mm]和厚[5 mm]部分)图像,用于存在各种类型的颅内出血。比较了阳性变量的比例,并通过麦克马尔测试和由应急表确定的敏感性计算的差异。分析随机选择的出血病变以进行对比度指数(CI)。薄膜190KeV图像在检测到软骨血肿(SDH)(P 0.53)和超轴上血肿的CI大增加(COHEN的D> 0.86)。我们的结果表明,与标准120 kV图像相结合的虚拟高单色(190keV,薄截面)图像可以提供最佳的诊断性能,用于评估涉嫌TBI的患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号