Experimental investigation of solar assisted ground source heat pump system has been carried out to understand performance variation during space heating for continuous eight hours operation from morning to evening for Indian winter climatic conditions. Heat extraction rate from solar collector and ground exchanger were monitored from 9 AM to 5 PM on hourly basis by measuring the inlet and outlet temperatures of heat transfer fluids. A detailed thermodynamic energy balance carried out on hourly basis indicates maximum heat loss is observed at 12 noon at which maximum heat extraction from solar collector and ground heat exchanger was obtained. Maximum COP of the SAGSHP system is observed at 12 noon for all the three mass flow rates, however, the COP decreases up to 3 % with increase in severity of winter due to increase in heat loss. About 44 % increase in mass flow rate of heat carrying fluids has enhanced the heat extraction rate up to 18 %, resulting in about 3 % increase in room temperature. The SAGSHP system was able to maintain the room temperature at about 20 to 21 A degrees C when the ambient temperature was at about 12 degrees C.
机译:太阳能辅助地源热泵系统的实验研究已经开展了了解在早晨到晚上连续八小时运行的空间加热过程中的性能变化。通过测量热传递流体的入口和出口温度,每小时监测来自太阳能收集器和地面交换机的热提取率。在小时基础上进行的详细热力学能量平衡表明在中午12中观察到最大热损失,其中获得了太阳能收集器的最大热量和地热交换器。在中午12中观察到SAGSHP系统的最大COP,但是,由于热量损失的增加,COP减少了高达3%的冬季严重程度。热携带流体质量流量增加约44%,增强了高达18%的热萃取率,​​导致室温增加约3%。当环境温度为约12摄氏度时,SAGSHP系统能够将室温保持在约20至21℃。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号