This paper describes a novel percutaneous ultrasound gastrostomy (PUG) procedure and the CoapTech point-of-care ultrasound magnet-aligned gastrostomy (PUMA-G) device, which were developed to allow the placement of gastrostomy tubes by physicians across a variety of specialties, using ultrasound equipment found in many nonspecialized medical locations while consuming fewer resources. The current practice for the placement of gastrostomy tubes requires highly specialized equipment and trained physicians, which can delay the performance of the procedure or make it inaccessible in some locations. The PUMA-G device consists of an orogastric catheter with a balloon that encloses a magnetic bar at its distal end and an external, handheld magnet. The orogastric tube is passed through the mouth or the nose and into the stomach. The external magnet is then used to maneuver the balloon to the desired location in the stomach, with feedback and guidance from real-time ultrasound visualization. The novelty of this approach is the use of magnets to create the static compressive force needed for coaptation, in which the stomach is pushed flush against the abdominal wall, allowing ultrasound visualization of the entire gastrostomy tract (skin to stomach), safe cutaneous puncture, and guidewire-assisted placement of the gastrostomy tube. The development of the PUMA-G device has been aided by benchtop and simulation testing in addition to canine and human cadaver studies. The PUMA-G device was used successfully in 29 of 30 cadaver tests, with the one failure attributed to operator error and not the device. Further testing in live patients will assess the safety of the procedure, the speed with which it can be completed, the cost savings, and other benefits the device might offer over the existing gastrostomy procedures.
机译:本文描述了一种新型经皮超声胃术(PUG)程序和COAPTECH的护理点超声磁体排列的胃造口术(PUMA-G)装置,其开发为允许在各种特色的医生填充胃造术管,使用许多非专业医疗地点发现的超声设备,同时消耗更少的资源。目前对胃造口管放置的实践需要高度专业化的设备和培训的医生,可以延迟程序的性能或使其在某些位置无法进入。 PUMA-G器件由具有球囊的蠕动导管组成,该球囊在其远端和外部手持磁体处包围磁棒。蠕动管穿过嘴或鼻子并进入胃。然后,外部磁铁将气球操纵到胃中的所需位置,具有来自实时超声可视化的反馈和引导。这种方法的新颖性是使用磁铁来产生辅助所需的静态压缩力,其中胃被推动腹壁冲洗,允许整个胃术道(皮肤到胃部)的超声形象化,安全的皮肤穿刺,和导丝辅助放置胃造口管。除了犬和人类尸体研究外,Buma-G器件的开发已经受到Benchtop和仿真测试。 PUMA-G器件成功使用30个尸体测试中的29个,其中一个故障归因于操作员错误而不是设备。实时患者的进一步测试将评估程序的安全性,可以完成它的速度,节省成本和其他益处,该装置可能提供现有的胃造术手术。

著录项

  • 来源
    《Journal of Medical Devices》 |2019年第2期|共6页
  • 作者单位

    Univ Maryland Sch Med Dept Emergency Med 110 South Paca St 6th Floor Suite 200 Baltimore MD 21201 USA;

    Johns Hopkins Univ Dept Anesthesiol &

    Crit Care Med Sch Med 600 North Wolfe St Meyer 297 Baltimore MD 21287 USA;

    Johns Hopkins Univ Sch Med Armstrong Inst Patient Safety &

    Qual 750 East Pratt St 15th Floor Baltimore MD 21202 USA;

    Johns Hopkins Univ Sch Engn Baltimore MD 21218 USA;

    Johns Hopkins Univ Sch Engn Baltimore MD 21218 USA;

    Univ Maryland Sch Med Dept Emergency Med 110 South Paca St 6th Floor Suite 200 Baltimore MD 21201 USA;

    CoapTech 8 Market Pl Suite 804 Baltimore MD 21202 USA;

    Univ Maryland Sch Med Dept Emergency Med 110 South Paca St 6th Floor Suite 200 Baltimore MD 21201 USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 仪器、设备;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号