Design and application of a novel patient-specific 3D printed drill navigational guiding template in percutaneous thoracolumbar pedicle screw fixation: A cadaveric study

机译:专用患者特异性3D印刷钻探导航模板的设计与应用在经皮后胸椎弓根螺钉固定:尸体研究

获取原文
获取原文并翻译 | 示例
           

摘要

The conventional surgical method of percutaneous pedicle screw fixation (PPSF) mainly uses X-ray fluoroscopy guidance to target the vertebral pedicle for screw placement. This study aimed to explore the feasibility of establishing a personalized drill guide template for PPSF based on a three-dimensional (3D) printing technique and to evaluate the accuracy and safety of the method for assisting screw insertion in cadaveric specimens. The T3-L3 trunk cadaveric specimens from six adults were subject to a computed tomography (CT) scan in the prone position. A three-dimensional model containing the back skin contour was reconstructed. A bilateral ideal pedicle screw in the T6-L1 segment was designed. Then, the reverse templates were designed. The two templates were fused and printed into an individualized guide template. PPSF was performed under the assistance of the guide template, and the CT scan was taken postoperatively to access the screw position. Ninety-six pedicle screws were successfully placed on the bilateral vertebral body of the T6-L1 segment with the assistance of a guide template. The guide plate was not loosened or displaced when operated by a single hand, and the operation time was 24.6 +/- 7.9 s. The axial CT images after puncture indicated that in 96 puncture needles, 90 needles were grade I and 6 were grade II, with a puncture accuracy rate of 98.6%. In conclusion, an individualized PPSF navigation template was developed using Mimics software and 3D printing prototyping, which improved the accuracy of PPSF in cadaveric specimens. (C) 2020 Elsevier Ltd. All rights reserved.
机译:经皮椎弓根螺钉固定(PPSF)的传统手术方法主要使用X射线透视引导来靶向椎椎弓根螺钉放置。本研究旨在探讨基于三维(3D)印刷技术的PPSF建立个性化钻头指南模板的可行性,并评估尸体标本中螺杆插入的方法的准确性和安全性。来自六名成人的T3-L3尸体尸体标本在易于位置进行计算断层扫描(CT)扫描。重建了包含背部皮肤轮廓的三维模型。设计了T6-L1段的双边理想椎弓根螺钉。然后,设计了反向模板。两个模板融合并打印到个性化指南模板中。 PPSF在指导模板的辅助下进行,并且CT扫描被术后采取,以进入螺杆位置。在指导模板的帮助下成功地放置在T6-L1段的双侧椎体上的九十六颗螺钉。当由单手操作时,导板不会松开或移位,操作时间为24.6 +/- 7.9 s。穿刺后的轴向CT图像表明,在96个穿刺针中,90针级I和6级是II级,刺穿精度率为98.6%。总之,使用模仿软件和3D打印原型开发了个性化的PPSF导航模板,其提高了尸体标本中PPSF的准确性。 (c)2020 elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号