首页> 外文期刊>Journal of cardiovascular electrophysiology >Ablation index‐guided 50?W ablation for pulmonary vein isolation in patients with atrial fibrillation: Procedural data, lesion analysis, and initial results from the FAFA AI High Power Study
【24h】

Ablation index‐guided 50?W ablation for pulmonary vein isolation in patients with atrial fibrillation: Procedural data, lesion analysis, and initial results from the FAFA AI High Power Study

机译:消融指标导向50?W消融心房颤动患者肺静脉分离:程序数据,病变分析和FAFA AI高功率研究的初始结果

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Background Radiofrequency high‐power ablation appears to be a novel concept for atrial fibrillation (AF). The ablation index (AI) value has been associated with durability of pulmonary vein isolation (PVI). Objectives This study aimed to report the procedural data and initial results of a combined ablation technique using AI‐guided high‐power (AI‐HP; 50?W) ablation for PVI. Methods Symptomatic AF patients were consecutively enrolled and underwent wide‐area contiguous circumferential PVI. Contact‐force catheters were used, ablation power was set to 50?W targeting AI values (550 anterior and 400 posterior). Esophageal temperature was monitored during procedure, all patients underwent postablation esophageal endoscopy. Results PVI was achieved in all (n?=?50, mean age: 68?±?9 years, female: 60%) patients, rate of first‐round PVI was 92%. A total of N?=?2105 AI‐guided ablation lesions were analyzed. Comparing left anterior wall vs left posterior wall and right anterior wall vs right posterior wall, mean ablation time (s) per lesion was 20.5?±?8 vs 8.6?±?3 and 12.2?±?4 vs 9.3?±?3; mean contact force (g): 17.1?±?12 vs 25.4?±?14 and 33.7?±?13 vs 21.0?±?11; mean AI: 547?±?48 vs 445?±?55 and 555?±?56 vs 440?±?47 (all P ??.0001). Procedure and fluoroscopy time (minute) were 55.6?±?6.6 and 6?±?1.7, respectively. Only one (2%) patient had a minimal esophageal lesion. During In‐hospital and 1‐month follow‐up no major complications such as death, stroke, tamponade, or atriaesophageal fistula (AE) occurred. Preliminary 6‐month follow‐up showed 48 of 50 (96%) patients were free from clinical AF/atrial tachycardia recurrence. Conclusion AI‐HP (50?W) ablation appears to be a feasible, safe, fast, and effective ablation technique for PVI.
机译:摘要背景射频高功率消融似乎是心房颤动(AF)的新颖概念。消融指标(AI)值与肺静脉分离(PVI)的耐久性有关。目的本研究旨在通过AI-Guided大功率(AI-HP;50μl)消融PVI来报告组合消融技术的程序数据和初始结果。方法对症状AF患者连续注册和接受广域邻接圆周PVI。使用接触力导管,将消融功率设定为50°W靶向AI值(550前部和400个后部)。在程序期间监测食管温度,所有患者接受了后疗法食管内窥镜检查。结果PVI全部达到(N?= 50,平均年龄:68?±9年,女性:60%)患者,第一轮PVI率为92%。分析了总共N?= 2105 AI导向消融病变。比较左侧壁与左后壁和右侧壁对右后壁,平均偏见的平均烧蚀时间为20.5?±8 vs 8.6?±3和12.2?±4 vs 9.3?±3;平均接触力(g):17.1?±12 vs 25.4?±14和33.7?±13 vs 21.0?±11;平均值ai:547?±48 vs 445?±55和555?±56 vs 440?±47(所有p?0001)。过程和透视时间(分钟)分别为55.6?±6.6和6?±1.7。只有一个(2%)患者有一个最小的食管病变。在医院内和1个月的随访中,没有发生死亡,中风,局部障碍或Atriaeophageal瘘(AE)的主要并发症。初步6个月的随访显示,50例(96%)患者的48名(96%)免于临床AF /心房心动过速复发。结论AI-HP(50次)消融似乎是PVI可行,安全,快速,有效的消融技术。

著录项

  • 来源
  • 作者单位

    Cardioangiologisches Centrum Bethanien (CCB)Frankfurt Academy For Arrhythmias (FAFA)Frankfurt am;

    Cardioangiologisches Centrum Bethanien (CCB)Frankfurt Academy For Arrhythmias (FAFA)Frankfurt am;

    Cardioangiologisches Centrum Bethanien (CCB)Frankfurt Academy For Arrhythmias (FAFA)Frankfurt am;

    Cardioangiologisches Centrum Bethanien (CCB)Frankfurt Academy For Arrhythmias (FAFA)Frankfurt am;

    Cardioangiologisches Centrum Bethanien (CCB)Frankfurt Academy For Arrhythmias (FAFA)Frankfurt am;

    Cardioangiologisches Centrum Bethanien (CCB)Frankfurt Academy For Arrhythmias (FAFA)Frankfurt am;

    Department of Cardiology and ElectrophysiologyAcibadem City Clinic Cardiovascular CenterSofia;

    Department of Cardiology and ElectrophysiologyAcibadem City Clinic Cardiovascular CenterSofia;

    Cardioangiologisches Centrum Bethanien (CCB)Frankfurt Academy For Arrhythmias (FAFA)Frankfurt am;

    Cardioangiologisches Centrum Bethanien (CCB)Frankfurt Academy For Arrhythmias (FAFA)Frankfurt am;

    Cardioangiologisches Centrum Bethanien (CCB)Frankfurt Academy For Arrhythmias (FAFA)Frankfurt am;

    Cardioangiologisches Centrum Bethanien (CCB)Frankfurt Academy For Arrhythmias (FAFA)Frankfurt am;

    Cardioangiologisches Centrum Bethanien (CCB)Frankfurt Academy For Arrhythmias (FAFA)Frankfurt am;

    Cardioangiologisches Centrum Bethanien (CCB)Frankfurt Academy For Arrhythmias (FAFA)Frankfurt am;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 人体生理学;
  • 关键词

    ablation; ablation index; atrial fibrillation; high power; pulmonary vein isolation;