首页> 外文期刊>AJR: American Journal of Roentgenology : Including Diagnostic Radiology, Radiation Oncology, Nuclear Medicine, Ultrasonography and Related Basic Sciences >Comparison of computer-aided detection to double reading of screening mammograms: review of 231,221 mammograms.
【24h】

Comparison of computer-aided detection to double reading of screening mammograms: review of 231,221 mammograms.

机译:比较计算机辅助检测与筛查乳房X线照片的双重读取:审查231,221乳房X线照片。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: This study compares the efficacy of single reading with computer-aided detection (CAD) to double reading and also to the first reader (without CAD) in a double-reading program. MATERIALS AND METHODS: A review was performed of 231,221 screening mammograms interpreted by experienced mammographers from 2001 through 2005 in a community-based mammography program. In 112,413 (48.6%), mammographers performed the first of two readings. In 118,808 (51.4%), they performed a single reading aided by CAD. RESULTS: For double reading, the first reader's recall rate was 10.2%; sensitivity, 81.4%; positive predictive value, as a percentage of positive screening mammograms resulting in a tissue diagnosis of cancer within 1 year (PPV(1)), 4.1%; and cancer detection rate, 4.12 per 1,000. After the double-reading process, the final recall rate was 11.9%; sensitivity, 88.0%; PPV(1), 3.7%; and cancer detection rate, 4.46 per 1,000. For single-reading with CAD, the recall rate was 10.6%; sensitivity, 90.4%; PPV(1), 3.9%; and cancer detection rate, 4.20 per 1,000. Statistically significant results included a lower recall rate with CAD compared with double reading (10.6% vs 11.9%, respectively; p < 0.0001); increased sensitivity with CAD compared with the first reader (90.4% vs 81.4%, p < 0.0001); and increased recall rate with CAD compared with the first reader (10.6% vs 10.2%, p < 0.0001). CONCLUSION: Double reading increased sensitivity with a modest increase in the recall rate compared with single reading. Single reading with CAD, compared with double reading, resulted in a small, but not statistically significant, increase in sensitivity with a lower recall rate. Our results indicate that CAD enhances performance of a single reader, yielding increased sensitivity with only a small increase in recall rate.
机译:目的:本研究将单次阅读与计算机辅助检测(CAD)的功效进行了比较,并将其与双重阅读程序中的第一个阅读器(无CAD)进行了比较。材料与方法:回顾性回顾了2001年至2005年间,由经验丰富的乳房X射线摄影者在一个社区乳房X射线摄影程序中解释的231,221幅乳腺X线照片。在112,413(48.6%)中,乳房X光检查人员进行了两次读数中的第一个。在118,808(51.4%)中,他们在CAD的帮助下进行了一次阅读。结果:进行双重阅读时,第一读者的回忆率为10.2%;灵敏度为81.4%;阳性预测值,占在1年内导致癌症组织诊断的X线筛查X线照片的阳性百分比(PPV(1)),为4.1%;癌症检出率是每千人4.12。经过复读,最终召回率为11.9%;灵敏度为88.0%; PPV(1),3.7%;癌症检出率是每千人4.46。对于使用CAD的单次阅读,召回率为10.6%;灵敏度为90.4%; PPV(1),3.9%;癌症检出率是每千人4.20。具有统计学意义的结果包括与重复阅读相比,CAD的召回率更低(分别为10.6%和11.9%; p <0.0001);与第一个阅读器相比,CAD的敏感性更高(90.4%对81.4%,p <0.0001);与第一个阅读器相比,使用CAD的召回率提高了(10.6%vs 10.2%,p <0.0001)。结论:与单读相比,双读提高了灵敏度,召回率有所提高。与重复阅读相比,使用CAD进行的单次阅读会导致灵敏度的提高,但在统计上并不显着,并且召回率较低。我们的结果表明,CAD增强了单个阅读器的性能,从而提高了灵敏度,而召回率只有很小的提高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号