Fracture Strength of Implant Screw-Retained All-Ceramic Crowns with the Use of the Angulated Screw Channel: A Pilot Study

机译:植入物螺钉保留的全陶瓷冠部的断裂强度随着成角度的螺杆通道:试验研究

获取原文
获取原文并翻译 | 示例
           

摘要

To correct for angulation discrepancies in the maxilla, implant companies have designed angulated screw channel (ASC) abutments. The design of these abutments allows for the restorative screw channel to be placed up to 25 degrees off the center axis of the implant. Minimal independent research has been published to evaluate the fatigue resistance of this implant-abutment connection. This study evaluated the fracture strength of a newly designed zirconia crown with a 25-degree angulated screw channel (n = 5) vs a straight channel (n = 5). Each specimen was subjected to an off-axis compression load from an MTS cyclic loading machine with a custom-designed indenter simulating a natural dentition. All the 25-degree angulated screw channel specimens failed, with four of the five (80%) catastrophically failing. Four of the five straight-channel specimens failed, with two of the five (40%) catastrophically failing. Results revealed the potential abutment fracture from internal stresses at the screw-zirconia and metallic-zirconia interfaces. Further research is needed to test the use of all-ceramic crowns with the use of the angulated screw channel.
机译:为了纠正Maxilla中的角度差异,植入公司设计了角度螺钉通道(ASC)基台。这些支座的设计允许恢复螺杆通道放置在植入物的中心轴上高达25度。已经公布了最小的独立研究以评估这种植入物连接的疲劳性。该研究评估了具有25度角质螺钉通道(n = 5)的新设计的氧化锆冠的断裂强度Vs直通通道(n = 5)。将每个样本从MTS循环装载机进行脱轴压缩载荷,其具有模拟自然牙列的定制设计的缩进。所有25度的角度螺旋通道样本都失效,五个中有四个(80%)灾难性地失败。五个直频标本中的四种失败,其中两个五(40%)灾难性地失败。结果揭示了螺杆氧化锆和金属 - 氧化锆接口的内应力潜在的邻接骨折。需要进一步的研究来测试所有陶瓷冠与有角色螺钉通道的使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号