首页> 外文期刊>Surgical innovation >Simball Box for Laparoscopic Training With Advanced 4D Motion Analysis of Skills
【24h】

Simball Box for Laparoscopic Training With Advanced 4D Motion Analysis of Skills

机译:用于腹腔镜训练的Simball盒,具有高级4D运动的技能分析

获取原文
获取原文并翻译 | 示例
           

摘要

Background. Laparoscopic skills training and evaluation outside the operating room is important for all surgeons learning new skills. To study feasibility, a video box trainer tracking 4-dimensional (4D) metrics was evaluated as a laparoscopic training tool. Method. Simball Box is a video box trainer with authentic surgical instruments and camera with video recording, equipped with 4D motion analysis registered through trocars using machine vision technology. Residents attending a 3-day laparoscopy course were evaluated performing a laparoscopic surgical knot at start, middle, and end. Metrics were obtained. Feedback data were presented in reference to expert/tutorial performance. Results. Ten right-handed residents were included. Median time (range) to finish the task was 359 (253-418), 129 (95-166), and 95 (52-156) seconds; 655%, 236%, and 174% of tutorial performance, with significance pre-/midcourse (P<.0001), pre-/postcourse (P<.0001), and mid-/postcourse (P=.0050). Combined median total instrument motion decreased pre-/midcourse from 1208 (845-1751) to 522 cm (411-810 cm); P=.042 to 405 cm (246-864 cm) postcourse; pre-/postcourse P<.0001; 673%, 291%, 225% of tutorial performance. Total angular distance in radians (range) was 150 (87-251), 65 (42-116), and 50 (33-136) with significance pre-/midcourse (P=.022) and pre-/postcourse (P=.0002). Right-handed average speed (cm/s) increased: 1.94 (1.11-2.27) pre-, 2.39 (1.56-2.83) mid-, 2.60 (1.67-3.19) postcourse with significance pre-/midcourse (P=.022) and pre-/postcourse (P=.002). Average acceleration (mm/s(2)) and motion smoothness (mu m/s(3)) failed to show any difference. Conclusion. For laparoscopic training and as a promising evaluation device, Simball Box obtained metrics mirroring progression well.
机译:背景。手术室外的腹腔镜技能培训和评估对于学习新技能的所有外科医生都很重要。为学习可行性,将视频盒训练器跟踪4维(4D)指标评估为腹腔镜训练工具。方法。 Simball Box是一个带有正宗手术器械和带视频录制的摄像机的视频盒训练器,配备了通过使用机器视觉技术的轨道登记的4D运动分析。在开始,中间和结束时评估参加3天腹腔镜检查课程的居民进行腹腔镜手术结。获得了指标。参考专家/辅导性能提出反馈数据。结果。包括十个右撇子居民。完成任务的中位时间(范围)是359(253-418),129(95-166)和95(52-156)秒; 655%,236%和174%的辅导性能,具有重要意义(P <.0001),预/后(P <.0001)和中/后(P = .0050)。组合中值总仪器运动从1208(845-1751)到522厘米(411-810厘米)下降预/中间仪器; P = .042至405厘米(246-864厘米)的邮政; Pre- / PostCourse P <.0001; 673%,291%,辅导性能的225%。弧度(范围)中的总角度距离为150(87-251),65(42-116)和50(33-136),其显着性预/中间/中间(P = .022)和/ postcourse(P = .0002)。右手平均速度(CM / S)增加:1.94(1.11-2.27)预先,2.39(1.56-2.83),2.60(1.67-3.19)的往期意义(p = .022)和预/后(p = .002)。平均加速度(mm / s(2))和运动平滑度(mu m / s(3))未能显示任何差异。结论。对于腹腔镜训练和作为有前途的评估装置,Simball Box获得了镜面镜头镜头的度量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号